Reading operation setting, Tuning target code settings – KEYENCE SR-750 Series User Manual

Page 77

Advertising
background image

77

E SR-750 UM

„

Reading operation setting

JAN/EAN/UPC settings

350

0,1

UPC-E reading

0 : Disable
1 : Enable

1

351

0,1

EAN/JAN 8 digits reading

0 : Disable
1 : Enable

1

352

0,1

EAN/JAN 13 digits reading

0 : Disable
1 : Enable

1

353

0,1

UPC-A Output

0 : Output in 13 digits
1 : Output in 12 digits

0

354

0,1

Add "number system" to UPC-E

0 : Disable
1 : Enable

0

355

0,1

2-digit supplemental

0 : Disable
1 : Enable

1

356

0,1

5-digit supplemental

0 : Disable
1 : Enable

1

357

0,1

Ignore UPC without supplemental

0 : Disable
1 : Enable

0

358

0,1

GTIN compatible 14-digit output

0 : Disable
1 : Enable

0

CODE128 settings

366

0,1

GS1-128

0 : Disable
1 : Enable

1

Function

Command

Number

Setting

value

Explanation

Default

Alternate

600

0, 1

0 : Disable
1 : Enable

0

Internal bank retry
count

601

00 to 32

00

Decode timeout
duration

602

0001 to
0255

Specify in units of 10 ms

0010

Scan delay time

603

000 to 255 Specify in units of 1 ms

000

Decoding area

604

aaabbbcccddd

aaa : 000 to 650 (Even only)
bbb : 000 to 378 (Even only)
ccc : 101 to 751 (Odd only)
ddd : 101 to 479 (Odd only)
* The minimum size is 100 dots ×

100 dots.

000000751479

Inverse

605

0, 1

0 : Disable
1 : Enable

0

Reverse

606

0, 1

0 : Disable
1 : Enable

0

Base tilt angle

607

0 to 359

Unit: 1 degree

0

Tilt angle range

608

0 to 180

Unit: 1 degree
* Base tilt angle ± Tilt angle range

will be enabled.

180

Grid correction

500

0,1

0 : Disable
1 : Enable

1

Quiet zone scale factor

611

Other than
GS1 DataBar:
4 to 11
GS1 DataBar:
0 to 11

Quiet zone scale factor (x 1)
*Barcode only
• Other than GS1 DataBar:

Applied to the quiet zones at
both ends

• GS1 DataBar: Applied to the

right quiet zone of DataBar
Limited

Depends

on the

code type.

Function

Command

Number

Setting

value

Explanation

Default

(aaa, bbb)

(ccc, ddd)

Format of the Code Setting Command for Tuning (WC/RC)

Send the code setting command for tuning in the following formats.
• Configuration change

Send command

Response

Normal process

Abnormal process

• Configuration confirmation

Send command

Response

Normal process

Abnormal process

mm : Command number 2-byte fixed
nnn : Setting value (changeable according to the command number)

example) Setting the maximum read length to 1000 digits

Configuration change

Send command

WC, 0100, 1000

Response (Normal process) OK, WC

Configuration confirmation Send command

RC, 0100

Response (Normal process) OK, RC, 1000

„

Tuning target code settings

Function

Command

Number

Setting

value

Explanation

Default

QR code settings

0100

0001 to
7089

Maximum read length

7089

0101

0001 to
7089

Minimum read length

1

DataMatrix code
settings

0200

0001 to
3116

Maximum read length

3116

0201

0001 to
3116

Minimum read length

1

GS1 DataBar settings

0500

01 to 77 Maximum read length

77

0501

01 to 77 Minimum read length

1

0502

0 to 11

GS1 DataBar Limited Right quiet
zone scale factor setting

5

0503

0,1

GS1 DataBar Omnidirectional/
Truncated

0 : Disable
1 : Enable

1

0504

0,1

GS1 DataBar Stacked/
StackedOmnidirectional

0 : Disable
1 : Enable

1

0505

0,1

GS1 DataBar Limited

0 : Disable
1 : Enable

1

0506

0,1

GS1 DataBar Expanded

0 : Disable
1 : Enable

1

0507

0,1

GS1 DataBar ExpandedStacked

0 : Disable
1 : Enable

1

0508

2 to 11

GS1 DataBar Expanded Stacked
(Number of rows) minimum

2

0509

2 to 11

GS1 DataBar Expanded Stacked
(Number of rows) maximum

11

CODE39 settings

0600

03 to 50 Maximum read length

50

0601

03 to 50 Minimum read length

3

0602

4 to 11

Quiet zone scale factor

7

0603

0,1

Send start/stop characters

0 : Disable
1 : Enable

0

0604

0,1

Inspect check-digit

0 : Disable
1 : Enable

0

0605

0,1

Send check-digit

0 : Disable
1 : Enable

1

0607

0,1

Full ASCII conversion

0 : Disable
1 : Enable

0

ITF settings

0700

02 to 50 Maximum read length

50

0701

02 to 50 Minimum read length

6

0702

4 to 11

Quiet zone scale factor

7

0703

0,1

Inspect check-digit

0 : Disable
1 : Enable

0

0704

0,1

Send check-digit

0 : Disable
1 : Enable

1

WC

,

mmmm

,

nnn…

OK

,

WC

ER

,

WC

,

ee

ee: Error code

RC

,

mmmm

OK

,

RC

,

nnn…

ER

,

RC

,

ee

ee: Error code

Advertising