1 sr-750 series specifications, General specifications, Reading range characteristics (typical) – KEYENCE SR-750 Series User Manual

Page 116: Sr-750 series specifications, Sr-750, Sr-751, Sr-752

Advertising
background image

116

E SR-750 UM

15-1

SR-750 Series Specifications

General Specifications

*1 Barcodes fitted into the visual field range in size can be read.
*2 The laser classification for FDA(CDRH) is implemented based on IEC60825-1

in accordance with the requirements of Laser Notice No.50.

*3 To comply with CSA No.61010-1/UL61010-1/IEC61010-1, use the following power supply.

The power supply that provides Class 2 output as defined in the CEC and NEC,
or the power supply that has been evaluated as a Limited Power Source as
defined in CAN/CSA-C22.2 No.60950-1/UL60950-1/IEC60950-1.

*4 Peak operating current for PoE Power Class 2: 210mA maximum.

Model

SR-750HA SR-750

SR-751

SR-752 SR-752+

SR-75L4

SR-752+

SR-75L6

Type

High

resolution

Close-

range

Mid-

range

Long-

range

400 mm lens

attached

600 mm lens

attached

Receiver

Sensor

CMOS Image Sensor

Number of pixels

752×480 pixels

Lighting Light source

Red LED

Laser

pointer

Light source

Visible semiconductor laser, Wavelength 660 nm

Output

60

μW

Pulse duration

200

μs

Laser class

Class 1 Laser Product

(IEC60825-1, FDA(CDRH) Part 1040.10

*2

)

Reading

specifications

Supported

symbol

2D

QR, MicroQR, DataMatrix (ECC200), GS1 DataMatrix,

PDF417, MicroPDF, Composite code (CC-A, CC-B, CC-C)

Barcode

*1

GS1 Databar, CODE39, CODE39 FullASCII, ITF,

NW-7 (Codabar), CODE128, GS1-128, JAN/EAN/UPC,

CODE93, 2of5(Industrial 2of5), COOP 2of5,

Trioptic CODE39

Minimum

resolution

2D

0.082 mm 0.127 mm 0.19 mm

0.19 mm

0.33 mm

0.5 mm

Barcode

-

0.127 mm 0.127 mm 0.17 mm

0.22 mm

0.33 mm

Reading

distance

(typical

examples)

DataMatrix

QR

22 to 50 mm

(Cell size=

0.25 mm)

40 to 80 mm

(Cell size=

0.25 mm)

45 to 165 mm

(Cell size=

0.5 mm)

180 to 305 mm

(Cell size=

0.5 mm)

300 to 490 mm

(Cell size=

0.5 mm)

460 to 690 mm

(Cell size=

0.5 mm)

Barcode

-

30 to 100 mm

(Narrow bar

width

= 0.33 mm)

45 to 195 mm

(Narrow bar

width

= 0.5 mm)

180 to 330 mm

(Narrow bar

width

= 0.5 mm)

250 to 540 mm

(Narrow bar

width

= 0.5 mm)

400 to 760 mm

(Narrow bar

width

= 0.5 mm)

Focal distance

38 mm

60 mm

100 mm 250 mm

400 mm 600 mm

Reading view range

(focal distance)

26.6 mm×

17.0 mm

42.5 mm×

27.1 mm

70.6 mm×

45.0 mm

65.0 mm×

41.5 mm

108 mm×

69 mm

165 mm×

106 mm

I/O

specifications

Control

input

Points

2

Input type

Bidirectional voltage input

Maximum

rating

26.4 VDC

Minimum

ON voltage

15 VDC

Maximum

OFF current

0.2 mA or less

Control

output

Points

3

Output type

Photo MOS relay output

Maximum

rating

30 VDC

Maximum

load current

1 output: 50 mA or less, 3 Total output 100 mA or less

Leakage

current

when OFF

0.1 mA or less

Residual

voltage

when ON

1 V or less

Ethernet

Communication

standard

10BASE-T/100BASE-TX

Supported

protocol

TCP/IP, SNTP, FTP, BOOTP, MC Protocol,

KVSTUDIO, EtherNet/IP, PROFINET

Serial

communication

Communication

standard

RS-232C compliant

Transmission

speed

9600, 19200, 38400, 57600, 115200 bps

Synchronization

method

Asynchronous

Supported

protocol

Non-procedure, MC Protocol, SYSWAY, KVSTUDIO

Environmental

resistance

Enclosure rating

IP65

Ambient

temperature

0 to 45°C

Ambient storage

temperature

-10 to +50°C

Relative humidity

35 to 95% RH (No condensation)

Storage ambient

humidity

35 to 95% RH (No condensation)

Ambient luminance

Sunlight: 10000lx, Incandescent lamp: 6000lx, Fluorescent lamp: 2000lx

Operating

environment

No dust or corrosive gas present

Vibration

10 to 55 Hz Double amplitude 1.5 mm/55 to 500 Hz: Acceleration 5G,

3 hours each in X, Y and Z directions

Rating

Power voltage

*3

Control port: 24 V DC ±10% or

Ethernet port: PoE TypeA/B 36 to 57 V (Cannot supply at the same time)

Current

consumption

Control port: 220mA or less (When 24 VDC power supply is used)

Ethernet port: PoE Power Class 2

*4

Weight

Approx. 160 g

Approx.

175 g

Approx. 185 g

Reading range characteristics (Typical)

Reading distance with cell sizes (narrow bar width) other than the chart below can
be confirmed using the introduction guide for AutoID Network Navigator.
Refer to

"5-12 Installation Guide (Page 53)"

„

SR-750

Unit: mm

„

SR-751

Unit: mm

„

SR-752

Unit: mm

Code type

Cell size

Narrow bar width

A

B

DataMatrix, QR

0.127

50

70

025

40

80

Code39

0.127

46

74

0.33

30

100

Code128

0.25

34

90

Code type

Cell size

Narrow bar width

A

B

DataMatrix, QR

0.25

65

130

0.5

45

165

Code39

0.127

75

110

0.5

45

195

Code128

0.25

50

150

Code type

Cell size

Narrow bar width

A

B

DataMatrix, QR

0.19

220

260

0.25

210

270

0.33

200

280

0.5

180

305

Code39

0.17

220

260

0.25

180

330

Code128

0.25

195

275

40

30

20

10

–20

–30

–40

0

–10

100

50

0

B

A

Focal distance = 60 mm

Unit: mm

80

60

40

20

–40

–60

–80

0

–20

100

150

200

50

0

B

A

Unit: mm

Focal distance = 100 mm

40

30

20

10

–20

–30

–40

0

–10

200

250

300

150

0

B

A

Unit: mm

Focal distance = 250 mm

Advertising