12

E SR-750 UM

„

Bank prioritizing function

When the alternate setting order is set to "Begin with successful bank", the next
reading starts from the parameter bank of the most recent successful reading.
When codes with similar conditions are read in sequence, prioritizing according to
the last successful bank may result in a shorter reading processing time.

Operation of the bank prioritizing function when parameter banks 1 to 4 are
used
The reading order is changed to start reading from the parameter bank of the
previous successful reading.

Point

The bank prioritizing function is effective only in Operation mode.
The reading order is reset to the default setting when one of the
following operations is performed:
• Stopping the power supply
• Entering the test mode
• Entering Setting mode or Test mode
• Changing the alternate setting

3-4

Test Mode

This section describes the test mode of the SR-750 Series.

SR-750 Series Test Mode

For more information about the TEST button operations of the SR-750 Series or
the multiple LED status display, refer to

"3-1 Using the SR-750 Series (Page

9)".

Reference

• It is also possible to perform the test mode by specifying a parameter

bank.

"8-2 Operation Commands (Page 71)"

• If no parameter banks have setting values, the test mode is

performed for the parameter bank 0 (bank for read quick setup
code).

Online and offline modes

„

Offline mode

Offline mode is useful for fine-tuning the installation position, distance or angle
during initial setup.
Data is continuously output as long as the test is active.
The test result data is output in real time.

Function

Description

Reading rate test mode

Offline

Scans codes 10 times and measures the
reading rate according to the number of times
that the code was read correctly.

Offline

This test mode checks the number of
successful decodes against the number of
decodes attempted while the trigger input is
turned ON.

Read time test mode

Offline

This test mode measures the amount of
decode time that it takes to read a code and
outputs the result every 10 decodings are
performed.

Offline

This test mode measures the amount of time
that it takes to read a code and outputs the
result when the trigger input turns OFF.

Code position measurement
test mode

Offline

In this test mode, the level that indicates how
far the code shifts from the center of the field of
view is measured.

Reading

order

Parameter bank

No.

Reading

order

Parameter bank

No.

1

1

1

3

2

2

2

1

3

3

3

2

4

4

4

4

Reading
Success

Activate the test.

Stop the test.

Testing

Test operations

Testing

„

Online mode

Online mode is useful for troubleshooting issues during run-time operation.
Online test mode can only be enabled through serial command input.

"8-2 Operation Commands (Page 71)"

To begin the test, turn the timing input on. To end the test and output results, turn
the timing input off.

Test Mode Measurement Status

The measurement status of the test mode can be checked on the multiple LED
indicator.
The multiple LED displays the following symbols during test mode.

Test Mode Details

This section describes the advanced details of each test mode.

Reading rate test mode

This test mode scans codes and measures the number of successful reads.
The offline mode scans 10 times and outputs the number of successful reads.
The offline test mode outputs the reading rate which is obtained from the number of
decodes against the number of decodes attempted while the trigger input is ON.

The parameter bank switches while scanning, just as when reading with the
alternate function. When reading is successful, the parameter bank used for
reading is fixed and the reading rate is calculated.
When a read error occurs, the test mode switches to another parameter bank and
continues the measurement.

Multiple LED status

Reading rate

(%)

Processing

time (ms)

Code position

measurement

OK/NG/

ERROR LED

5 bars lit

90 to 100

Up to 99

LEVEL5

Green

4 bars lit

70 to 80

100 to 199

LEVEL4

Green

3 bars lit

50 to 60

200 to 299

LEVEL3

Green

2 bars lit

30 to 40

300 to 399

LEVEL2

Green

1 bar lit

10 to 20

400 or more

LEVEL1

Green

0 bars lit

Reading error

Red

Test commands

Timing operation

Testing

Testing

Activate the test.

Stop the test.

Timing ON