KEYENCE SR-750 Series User Manual

Page 80

Advertising
background image

80

E SR-750 UM

„

Data appending function setting

„

Verification/Preset function setting

Function

Command

Number

Setting

value

Explanation

Default

Time appending

300

0, 1

0 : Do not append
1 : Append

0

Code type appending

301

0, 1

0 : Do not append
1 : Append

0

Symbol ID appending

302

0, 1

0 : Do not append
1 : Append

0

Bank number
appending

303

0, 1

0 : Do not append
1 : Append

0

Scan count appending

305

0, 1

0 : Do not append
1 : Append

0

Read time appending

306

0, 1

0 : Do not append
1 : Append

0

Position level
appending

307

0, 1

0 : Do not append
1 : Append

0

Code vertex appending

308

0, 1

0 : Do not append
1 : Append

0

Code center appending

309

0, 1

0 : Do not append
1 : Append

0

Unused ECC ratio
appending

310

0, 1

0 : Do not append
1 : Append

0

Matching level
appending

312

0, 1

0 : Do not append
1 : Append

0

File name appending
(full path display)

313

0, 1

0 : Do not append
1 : Append

0

Burst number
appending

318

0, 1

0 : Do not append
1 : Append

0

Read detailed error
code appending

319

0, 1

0 : Do not append
1 : Append

0

Setting the function to
append ISO/IEC15415
verification result.

340

0, 1

0 : Do not append
1 : Append

0

Setting the function to
append ISO/IEC TR
29158 (AIM DPM-1-
2006) verification result.

341

0, 1

0 : Do not append
1 : Append

0

Setting the function to
append SAE AS9132
verification result

342

0, 1

0 : Do not append
1 : Append

0

Setting the function to
append SEMI T10-0701
verification result

343

0, 1

0 : Do not append
1 : Append

0

Setting for Master/Slave
group name addition

320

0, 1

0 : Do not append
1 : Append

0

Setting for Master/Slave
ID addition

321

0, 1

0 : Do not append
1 : Append

0

Data edit function (Data
edit by script)

360

0, 1

0 : Disable
1 : Enable

0

Function

Command

Number

Setting

value

Explanation

Default

Number of verification
start digits

400

0001 to
7089

0001

Number of verification
digits

401

000 to
494

Maximum value for sequential
value verification = 9

494

Preset data registration

402

hhhhhhhh··
·

Up to 494 characters (HEX 988
bytes) can be specified from HEX
(0x00 to 0x7F).
FF : Not set

FF

Verification method

403

0, 1

0 : Normal
1 : Sequential value verification

0

Incremental setting for
sequential value
verification

404

-9999 to
+9999

-9999 to +9999

+0001

„

Image data saving function setting

„

Other settings

Function

Command

Number

Setting

value

Explanation

Default

Saving destination of
read OK images

500

0, 3

0 : Disable saving
3 : FTP transmission

0

Saving destination of
verification NG images

501

0, 3

0 : Disable saving
3 : FTP transmission

0

Saving destination of
read error images

502

0 to 3

0 : Disable saving
1 : Saving to RAM
2 : Saving to ROM
3 : FTP transmission

1

Saving destination of
unstable images

503

0, 3

0 : Disable saving
3 : FTP transmission

0

Saving destination of
capture images

504

1, 3

1 : Saving to RAM
3 : FTP transmission

1

Image saving mode

505

0 to 2

0 : Latest bank image
1 : Specified number of images

after trigger input ON

2 : Specified number of images

after trigger input OFF

0

Specify the number of
images to save from
trigger input ON/OFF

506

01 to 10

10

Burst number to save
when burst read error
occurs

507

BBBBBBBB

B = 0, 1

0 : Disable saving
1 : Save

* Burst number 1 is on the top.

11111111

Edit image file name
function (Edit image file
name by script)

510

0, 1

0 : Disable
1 : Enable

0

Function

Command

Number

Setting

value

Explanation

Default

Output data on TEST
switch

600

0 : Disable
1 : Enable

1

Delimiter character

601

hh

Specify 1 character (2 HEX
characters) from (0x00 to 0x7F)

3A

Inter delimiter

602

hhhhhhh
h···

Specify up to 5 characters (10 HEX
bytes) from HEX (0x00 to 0x7F).
FF : Not set

2C

Data filling size

603

000 to
999

000

Data filling character

604

hh

Specify 1 character (2 HEX
characters) from (0x00 to 0x7F)

20

Silent Mode

606

0 to 255

0 : Not selected
1 : Verification OK, Read OK
2 : Verification NG
4 : Read ERROR
8 : Stable reading

16 : Unstable reading
32 : Preset result
64 : Test Mode

Specify the setting by sum of the
values of the items.

0

Reader name

607

hhhhhhh
h

Specify up to 8 characters (16 HEX
bytes) from UNICODE (UTF-16
BigEndian).
FF : Not set

005200450
041004400

450052

(READER)

Monitor output data
priority display position

609

0, 1

0 : Display data from front
1 : Display data from back

0

Trigger command
response character
string

610

0 to 2

0 : Default
1 : SR-600 compatible
2 : User setting

0

TUNE button lock

611

0, 1

0 : Disable lock
1 : Enable lock

0

Laser aimer setting by
TUNE button

612

0 to 3

0 : None
1 : Emit in test mode only
2 : Emit in operating mode only
3 : Emit always

3

Trigger command
success response
character string

613

hhhh…

Up to 8 characters can be
specified.
Specify characters with HEX (0x00
to 0x7F).

* This is valid when the trigger

command response character
setting is User setting.

4F4B

Trigger command
failure response
character string

614

hhhh…

4552

Camera rotation
settings

901

0, 1

0 : Normal Mode
1 : 180 degrees rotation

0

Advertising