E SR-750 UM

„

SNTP settings

Function

Command

Number

Setting

value

Explanation

Default

Remote SNTP server
address

520

a. b. c. d

a : 0 to 255
b : 0 to 255

c : 0 to 255

d : 0 to 255

If 0.0.0.0 is set, the SNTP server is
not accessed.

0.0.0.0

Time zone

521

0 to 33

0 to 32

0 : GMT-12:00
1 : GMT-11:00
2 : GMT-10:00
3 : GMT-9:00
4 : GMT-8:00 PSD
5 : GMT-7:00
6 : GMT-6:00 CST, Mexico City,

Central America

7 : GMT-5:00 EST
8 : GMT-4:30
9 : GMT-4:00 AST

10 : GMT-3:30

11 : GMT-3:00 Brasilia

12 : GMT-2:00 Central Atlantic
13 : GMT-1:00
14 : GMT London, UTC
15 : GMT+1:00 Berlin, Brussels,

Rome, Paris, Berne

16 : GMT+2:00 Athens,

Jerusalem

17 : GMT+3:00 Kuwait
18 : GMT+3:30
19 : GMT+4:00 Moscow
20 : GMT+4:30
21 : GMT+5:00
22 : GMT+5:30 New Delhi
23 : GMT+5:45
24 : GMT+6:00
25 : GMT+6:30
26 : GMT+7:00 Bangkok
27 : GMT+8:00 Kuala Lumpur,

Singapore, Taipei, Beijing

28 : GMT+9:00 Japan, Seoul
29 : GMT+9:30
30 : GMT+10:00 Canberra,

Sydney

31 : GMT+11:00
32 : GMT+12:00
33 : GMT+13:00

28

Update cycle (min)

522

1 to 99

1

Batch transmission of setting/confirmation commands (WA/RA)

The SR-750 Series has the dedicated command that has been prepared for batch
transmission of multiple setting/confirmation commands (WB/RB, WC/RC, WP/RP,
WN/RN). Use this command to reduce the number of times to send setting
commands.

Batch transmission command format

Send the batch transmission command in the following formats.
• Configuration change

Send command

Response

Normal process

Abnormal process

• Configuration confirmation

Send command

Response

Normal process

Abnormal process

Setting command 1, Setting command 2 : Setting command type
Confirmation command 1, Confirmation command 2 : Confirmation command type
n

: Location where an error

occurs Head 1

Error command type

: Type of command where an

error occurs

ee

: Error code

• When using the batch transmission command, the reflecting order of the setting

is the same as the sending order of the setting commands.

• Make sure to send the SAVE command after sending the batch transmission

command containing the communication setting command.

• The batch transmission command can send up to 2048 bytes of number of

characters (excluding header and terminator).

• The location (n) of the error command returns the location first confirmed from

the head of the transmission command.

Each Setting/Confirmation Command Format

When using the batch transmission command, link each setting/confirmation
command in the following format after deleting W/R from each command.

„

Parameter bank configuration command

Change command

Confirmation command

Confirmation command response

bb

: Parameter bank number 01 - 10 Fixed to 2 bytes

mmm : Command number Fixed to 3 bytes
nnn··· : Setting value (varies according to command

number)

„

Code configuration command for tuning

Change command

Confirmation command

Confirmation command response

A

: Code setting number 1 to 8 1-byte Fixed to 1 byte

mm

: Command number Fixed to 2 bytes

nnn··· : Setting value (changeable according to the

command number)

„

Operation configuration command

Change command

Confirmation command

Confirmation command response

mmm : Command number Fixed to 3 bytes
nnn··· : Setting value (varies according to command

number)

WA

,

Setting

command 1

,

Setting

command 2

,

OK

,

WA

ER

,

WA

,

n

,

Error

command type

,

ee

RA

,

Setting

command 1

,

Setting

command 2

,

OK

,

RA

,

Confirmation

command 1 response

,

Confirmation

command 2 response

,

ER

,

RA

,

n

,

Error

command type

,

ee

B

,

bb

mmm

,

nnn…

B

,

bb

mmm

B

,

bb

nnn…

C

,

A

mm

,

nnn…

C

,

A

mm

C

,

A

nnn…

P

,

mmm

,

nnn…

P

,

mmm

P

,

nnn…

Advertising