■ Preset point output performance (3J

The following is an example for preset point output (pubc out mode )

Note: Only

In CHse

of the converter for special specifications (refer to 7,3.3 '“Converter for

Special specifications'’), this preset point output (one shot pulse mode) can be selected,

Setting preset count; 100

Toiulizcr

flow counts

200

1ÜÜ

Preset point output

For it takes the time setied pulse

width from the outpul goes ON

ON

OFF

• The preset point output goes ON when Ihe totalizer counts reaches the preset point (100 in

this example). And the next preset point (200 in this example ; current preset point :100 and

preset count :100 makes 2(HJ) is setted. In this example repeat this process .

* The output goes OFF when it lakes the lime seited pulse width from the output goes ON.

NOTEi If preset pulse is setled and preset pulse width is longer than the interval of that totalizer

reaches the preset point, the output can't he form pulse out.

If pulse output is needed, set preset count according lo shown below.

Preset Pulse

Width

The Interval of

that Totalizer reaches

the Preset Point

tixample) Count rate;0.i) 1 I

Flow verosityilO 1/s

Totalizer count up rale: 1ms,'COUNT

.iOms

More than lOOms

l^esel Count;more than lOf)

300 ms

More ihan lOfMIms

Preset Count:more than ItHJO

1 2 6

-