Converter hardware failure

The system checks ihc internal drcuilry at the time of power-up for all error items and

checks eonliiiuously for the specified hems ys described belown If an error is detected, one

of the messages shown in the table below will be displayed,

If multiple errors occur, their messages will be displayed cyclically. The diagnostics items

concerning the excitation cable and excitation circuit are detected using the ADC circuit.

Thus, if the ADC fails. No. 4 (excitation cable) and No.

^

(excitation circuit) errors can

not be detected correctly. Further, this entire checking system is based on the CPU in the

flowmeter. Therefore, if the CPU fails, no accurate diagnostics or error message display

can he obtained.

No.

Error message

Description

Corrective action

1

* ROM ERROR *

ROM error

Internal componcnis or

printed'CTTOuit board must be
repaired or replaced.
Contact your nearest Toshiba

representative.

2

* RAM ERROR t

RAM error

3

PARAMETER FAIL

System parameter error

4

EX, CURR. OPEN

Excitation cables are not

connected,

Connect the excitation cables
correetJv.

S

EX, CURR, ERROR

An error occurred in the
excitation circuit.

Internal components or

printed-circuit board must be

repaired or replaced.

Contact your nearest 'Jbshiba

representative.

6

ADC, ERROR

ADC error

7

IliVALID TOTAL

Totalizer data was destroyed
due to external noise. (No
message appears if totalization

is not used )

I h c

error mc,ssagc disappears

if you pres,s the reset key.

NOTES

1

,

Errors No, 1 to No. 3 can be detected only at the time of power-up. The flowmeter

does not start measurement if any one of these errors is detected. If these errors

occur after powcf-up, the flowmeter cannot delect Ihese errors, and thus may

indicate and ouiput incorrect daui.

2,

Errors No, 4 to No. 6 may not be detected even if the errors result in incorrect

flowmeter accuracy, because of characteristic differences in components used to

delect these errors,

3.

C"PU error cannot be detected. If the CPU stops, the watchdog timer resets the

internal circuits and the flowjnctcr starts again from the initial power-up condition.

Depending on CPU condition, the flowmeter may not indicate and output correct

data.