IMPORTANT

(1) The grounding terminal of the LF434/Lr404 ilowmeter should be grounded with

100 ohm or less ground resistance. Use a heavy copper braid or wire

(cross-sectional area .S..'? inm' minimLim) to ground the icrminaJ and make it as

short as possible, ITie terminal is M4 size and an M4-size crimped ring lug should

be used to connect the wire to the lermina!. Avoid a comirion ground where earth

current may flow'. An independent ground is preferable. See Figure 5,2. fora

conductive pipeline grounding and non-conductive pipeline grounding procedures.

(2) To prevent a tw'o-point grounding, ground the shielded cable on the receiving

instrument side.

I

If conneetton pipe is conductive:

Conned between the grounding terminal

and both ends of the mating flanges with

a heavy copper braid or wire

{cross-section 5,5 mm" minimum).

If connection pipe is non-conductive:

Use u heavy copper braid or wdre

(cross-section 5.5 mm^ minimum) to

ground he terminal with 100 ohm or

Jess ground resistance.

-

2 8

-