üOl and D02 functions — One of the following functions can be assigned for DOl

(standard) and/or DO2 (option),

* PtiEse output (available only for DOl)

Pulse raie^ 3.6 to 36(100011 pulscs.^our

Pulse width: Ь,У to 5ÜÜ ms (but Jess than half of the period of pulse output for

100% flow rate)

* Mu It I-range selection oulpuls

One output used:

(1) 2-range switching fur unidirectional flow

(DOl or D02)

(2) Forward/Reverse flow range switching

Two outputs used:

(1) 4-range switching for unidirectional flow

(DOl and D02)

(2) 2-range switching for Forward and Reverse flows

* High and/or low limit alarms outputs

Outputs an alarm signal if the process flow rale goes above or

below the set limits. Output status is programmable,

Setting range: -10 to 11C% of tJic span (range)

Output status:

Kormal Open or Normal Close selected

« Empty pipe alarm output

Outputs an alarm signal when the dctccior pipe is not filled whth

fluid.

Output status:

Normal Open or Normal Close selected

* Preset point output

Outputs a signal when the totalized flow reaches the preset value.

Selling range:

1 to 999999^^ counts

Output status: Contact ÜN (closed)

* Converter failure alarm

Outputs a signal if an error occurs when self-diagnostics is

conducted.

Output status; Normal Open or Normal Close selected

Communications output

a ,small digital signal is superimposed on 4-20 mA current signal

(conformed to HAR'T protocol)

Loud resistance:

Load capacitance:

Ijoad inductancei

Cable length:

240 :o 1

0.25

p i F

maximum

4mH maximum

2km maximum (approximate value when 1,25mnr shielded

cable is used under standard operating condition)

Note: HART (Highway Addres,sable Remote Transducer) is a communications

protocol for industrial sensors recommended by IICF

(HART Cominuntcarioti Foundation),

Damping:

0,5 lo 60 seconds (selectable in increments of 1 second)

-