Comver – Canon MARKLL WUX10 User Manual

Page 29

Advertising
background image

Projector WUX10 MarkII User Commands

- 25 -

Revision History / Date

Changes

Revised by

Approved by

COMVER

User command version inquiry

Format

GETCOMVER / ?COMVER

Environment

Power

Input

OFF ON PM

D-RGB A-RGB1 A-RGB2 COMP

VIDEO

HDMI

None

- -

Response

Returns the user command version as

g:COMVER="<User command version:Character string>"

<User command version>:=99.9999

For details on other responses, refer to the "Error List".

Description

(1) This inquires about the user command version of the projector.
(2) This inquiry can be executed in any status provided that AC power is supplied to the projector.
(3) The user command version consists of a 2-digit number followed by a 4-digit number. Question

marks may appear in place of the numerals if the firmware has not been upgraded correctly.
(Example "??:????")

Example

> GET COMVER or ? COMVER
< g:COMVER="01.0000"

* Commands are indicated by ">", and responses are indicated by "<".