Tmpl – Canon MARKLL WUX10 User Manual

Page 78

Advertising
background image

Projector WUX10 MarkII User Commands

- 74 -

Revision History / Date

Changes

Revised by

Approved by

TMPL

Temperature limit inquiry

Format

GETTMPL

<n>

Number

0 to 255

<v>

Temperature value 0.0 to 127.9 °C

Environment

Power

Input

OFF ON PM

D-RGB A-RGB1 A-RGB2 COMP

VIDEO

HDMI

None

X O X

-

Response

Private commands (disclosed upon request)

Temperature limit is returned as '

g:TMPL=<n>{,<v>}

'

For details on other responses, refer to the "Error List".

Description

(1) This returns the limit value (of machine-stoppage) of each temperature sensors.
(2) Number of temperature sensors varies according to model.
(3) When returning multiple temperature sensor values, values will be separated with a comma.

There are cases when a number of sensors is 0. In this case, there will not be a comma.

(4) For correspondence of temperature sensor sequence and actual installation location, inquire

separately.

Example

Setting

None


Reference

> GET TMPL

This retrieves the temperature sensor limit values.

< g:TMPL=5,71.0,90.0,57.0,44.0,53.0