Testing the Job
Load material and press
Trial Piece so that you can check if the set-
up is correct.
You can make minor changes to the job settings at this stage if the
trial piece needs fine tuning. Press
Setup, then use the Prev (◄),
Next (►) and Change (+/-) buttons as required to modify job set-
tings. The chart below may help you fine tune your fold settings.
FOLD TYPE
ADDRESS TOO LOW
ADDRESS TOO HIGH
C — Letter Fold
Decrease Fold A
Increase Fold A and
increase Fold B by
the same amount
Z — Accordion
Increase Fold A
Decrease Fold A a
Fold
increase Fold B by
the same amount
Single Fold
Increase Fold A
Decrease Fold A
Double Fold
Decrease Fold A
Increase Fold A
We suggest you change the fold by 0.20 inches (5mm) each time
and run a new trial piece run to test the settings.
When you’ve made the necessary changes, press
Setup again to re-
turn to run mode. Your inserter system will save the job with the new