OMR • 3
3-15
SV61789 Rev.A
Setting Select/Supplementary Feeders
Press
Change (+/-) until you see
the option you want:
If sheet feeder 1 is the main/
scanning feeder, you can pro-
gram sheet feeder 2 and/or the
insert feeder for normal (one per
envelope) feeding or select feeding.
If sheet feeder 2 is the main/scanning feeder, you can program sheet
feeder 1 and/or the insert feeder for normal (one per envelope) feed-
ing or select feeding.
Select feed allows for one piece to be selectvely fed from either
feeder per envelope.
On Double Detect
Feeder on with the double detector operating, without select
feed. (The double detector stops the machine if more than
one sheet simultaneously feeds from the feeder.)
On SF Double Detect
Select feeder on with the double detector operating. (The
double detector stops the machine if more than one sheet
simultaneously feeds from the feeder.)
On SF
Select feeder on without the double detector.
Off
Feeder turned off for this job.
On
Feeder on without the double detector or select feed.
When the feeder is set as required, pressing
Next (►) will advance
to the sealer setting. Job programming then follows the normal se-
quence described from page 2-18 of this guide.