4 • reference – Pitney Bowes DI380 OfficeRight Systems User Manual

Page 66

Advertising
background image

4 • Reference

4-6

SV61789 Rev. A

5. Install the new upper felt.

Locate the tabs on the back

of the felt assembly in the

corresponding holes of the

mounting bar and slide the

felt toward the rear of the

machine. Make sure it has

fully latched into position.

6. Using the plastic tweezers

provided in the kit, remove

all four felts from the sealer

tank.

Discard these old felts.

7. Install the four new felts into

the sealer tank. They will

only fit one way. Make sure

to push them fully down into

the tank.

8. Push down on the blue tab

to return the upper felt as-

sembly to its operating posi-

tion. Make sure that the blue

latches (A) spring out and

fully latch into position.

9. Put the water bottle back into

position and close the covers.

The felts will take a few minutes to become fully wet and ready

for use.