4 • reference – Pitney Bowes DI380 OfficeRight Systems User Manual
Page 66
4 • Reference
4-6
SV61789 Rev. A
5. Install the new upper felt.
Locate the tabs on the back
of the felt assembly in the
corresponding holes of the
mounting bar and slide the
felt toward the rear of the
machine. Make sure it has
fully latched into position.
6. Using the plastic tweezers
provided in the kit, remove
all four felts from the sealer
tank.
Discard these old felts.
7. Install the four new felts into
the sealer tank. They will
only fit one way. Make sure
to push them fully down into
the tank.
8. Push down on the blue tab
to return the upper felt as-
sembly to its operating posi-
tion. Make sure that the blue
latches (A) spring out and
fully latch into position.
9. Put the water bottle back into
position and close the covers.
The felts will take a few minutes to become fully wet and ready
for use.
A