background image

Error and diagnosis

AX5805

99

4.2 Reason for shut-down CoE Objects 0xFA10:07 and

0xFA10:08

In order to determine the reason for shut-down, the sub-index 01 for the CoE Object 0xFA10 must be set to
0.

Value in
0xFA10:07
Reason for Axis 1
0xFA10:08
Reason for Axis 2

Description

0xXX00

Error reaction: no error reaction

0xXX40

Error reaction: STO (Safe Torque Off)

0xXX50

Error reaction: SS1 (Safe Stop 1)

0x01XX

Reason: the status word was calculated incorrectly

0x02XX

Reason: the parameters are incorrect or haven’t been loaded

0x03XX

Reason: the FSOE-Protocol is not in the DATA state

0x04XX

Reason: the internal comparison has failed. Re-check the motor and drive
dimensioning and parameterization

0x05XX

Reason: External Position Reference Cam was detected in an unexpected
location.

0x06XX

Reason position detection: the External Position Reference Cam was detected
at a position greater than the cam window

0x07XX

Reason position detection: the External Position Reference Cam was detected
at a position less than the cam window

0x08XX

Reason position detection: the axis has exceeded the defined maximum
allowable position range

0x50XX

Reason safety function: the safety function SS1 has been turned off

0x68XX

Reason safety function: the safety function SOS has been turned off.

0x80XX

Reason safety function: the safety function SSR has been turned off.

0x90XX

Reason safety function: the safety function SLS has been turned off.

0xA0XX

Reason safety function: the safety function SLP has been turned off.

0xA8XX

Reason safety function: the safety function SMS has been turned off.

0xB8XX

Reason safety function: the safety function SLI has been turned off.

0xC0XX

Reason safety function: the safety function SAR has been turned off.

0xC8XX

Reason safety function: the safety function SMA has been turned off.

0xD0xx

Reason safety function: the safety function SDIp has been turned off.

0xD1xx

Reason safety function: the safety function SDIn has been turned off.

Advertising