BECKHOFF AX5805 Installation User Manual

Page 43

Advertising
background image

Product description

AX5805

41

As soon as the safety function STO is activated, all torque is removed from the motor.

If the STO_Restart_Acknowledge_behavior parameter is set to TRUE, then the Restart_Acknowledge
control bit must be set in order for the axis to restart.

Note

Control

Bit Restart Acknowledge

The Restart Acknowledge control bit is not included in the standard mapping of the
AX5805. It must be additionally mapped into the user configurable range of the control
word.


Parameters for axis 1:

Index

Name

Description

Sub-
index

Unit

Default
value

0x6642

STO_Restart_
Acknowledge_behavior

If this parameter is set, the
AX5805 needs a
Restart_Acknowledge_Signal
after the STO function is called

--

--

FALSE

Parameters for axis 2:

Index

Name

Description

Sub-
index

Unit

Default
value

0x6E42

STO_Restart_
Acknowledge_behavior

If this parameter is set, the
AX5805 needs a
Restart_Acknowledge_Signal
after the STO function is called

--

--

FALSE

Advertising