4 Error and diagnosis

When it is activated, STO initiates a coast-to-stop action. No braking is applied to the connected motors; the
torque applied to the motor is switched off and the motor coasts to a stop. The time and distance it takes for
the motor to stop depends on the mechanics and kinetic energy present in the system. If there are loads
suspended from the motor, the motor may even be accelerated. The user must provide external safety
mechanisms (e.g. mechanical brakes) to prevent such inadvertent motion.

The reason for switching off can be read from the diagnostic data (CoE object 0xFA82). The data within this
object is divided into:

-

Diagnosis, and

-

Error

Error indices smaller than 0x1000 or larger than 0x4FFF are errors that can be reset by the transition of the
EtherCAT state from PREOP to SAFEOP. These include communication errors, parameter errors and
environment errors.

All other errors are internal errors that can only be reset by a hardware reset or by switching the AX5805 to
the EtherCAT state BOOT.

4.1 Error indices in CoE object 0xFA82

Error
index in
0xFA82

Error name

Description

Typical error
reaction time

0x0001

FAULT_MAXT_C1

The temperature has exceeded the
maximum permissible temperature (MC1).

0x0002

FAULT_MAXT_C2

The temperature has exceeded the
maximum permissible temperature (MC2).

0x0003

FAULT_MINT_C1

The temperature has fallen below the
minimum permissible temperature (MC1).

0x0004

FAULT_MINT_C2

The temperature has fallen below the
minimum permissible temperature (MC2).

0x0101

HW_ERR_MAX_VCC_C1

The supply voltage has exceeded the
maximum permissible voltage.

0x0102

HW_ERR_MAX_VCC_C2

The supply voltage has exceeded the
maximum permissible voltage.

0x0103

HW_ERR_MIN_VCC_C1

The supply voltage has fallen below the
minimum permissible voltage.

0x0104

HW_ERR_MIN_VCC_C2

The supply voltage has fallen below the
minimum permissible voltage.

0x0201

FAULT_MCTC1_TO

The MCTests of MC1 were not carried out
completely within the specified time

0x0202

FAULT_MCTC2_TO

The MCTests of MC2 were not carried out
completely within the specified time

0x0203

FAULT_TIMER_C1

The global timer was not updated in time.

0x0204

FAULT_TIMER_C2

The global timer was not updated in time.

0x020C

FAULT_TS_WDG_TO_C1

The TS module was not called within the
watchdog time.

0x020D

FAULT_TS_WDG_TO_C2

The TS module was not called within the
watchdog time.