82

AX5805

Parameters for axis 2:

Index

Name

Description

Sub-
index

Unit

Default value

0x6E91 t_SLS :001

Maximum time until the activation of the
SLS safety function

01

1 ms

0x0000

0x6E91 t_SLS :002

Maximum time until the activation of the
SLS safety function

02

1 ms

0x0000

0x6E91 t_SLS :003

Maximum time until the activation of the
SLS safety function

03

1 ms

0x0000

0x6E91 t_SLS :004

Maximum time until the activation of the
SLS safety function

04

1 ms

0x0000

0x6E91 t_SLS :005

Maximum time until the activation of the
SLS safety function

05

1 ms

0x0000

0x6E91 t_SLS :006

Maximum time until the activation of the
SLS safety function

06

1 ms

0x0000

0x6E91 t_SLS :007

Maximum time until the activation of the
SLS safety function

07

1 ms

0x0000

0x6E91 t_SLS :008

Maximum time until the activation of the
SLS safety function

08

1 ms

0x0000

0x6E93 n_SLS 32

Bit :001

Speed window for SLS_1

01

Increments
per ms

0x00000000

0x6E93 n_SLS 32

Bit :002

Speed window for SLS_2

02

Increments
per ms

0x00000000

0x6E93 n_SLS 32

Bit :003

Speed window for SLS_3

03

Increments
per ms

0x00000000

0x6E93 n_SLS 32

Bit :004

Speed window for SLS_4

04

Increments
per ms

0x00000000

0x6E93 n_SLS 32

Bit :005

Speed window for SLS_5

05

Increments
per ms

0x00000000

0x6E93 n_SLS 32

Bit :006

Speed window for SLS_6

06

Increments
per ms

0x00000000

0x6E93 n_SLS 32

Bit :007

Speed window for SLS_7

07

Increments
per ms

0x00000000

0x6E93 n_SLS 32

Bit :008

Speed window for SLS_8

08

Increments
per ms

0x00000000

0x6E94 t_L SLS

:001

Minimum time until the activation of the
SLS_1 safety function, if the speed is
within the window

01

1 ms

0x0000

0x6E94 t_L SLS

:002

Minimum time until the activation of the
SLS_2 safety function, if the speed is
within the window

02

1 ms

0x0000

0x6E94 t_L SLS

:003

Minimum time until the activation of the
SLS_3 safety function, if the speed is
within the window

03

1 ms

0x0000

0x6E94 t_L SLS

:004

Minimum time until the activation of the
SLS_4 safety function, if the speed is
within the window

04

1 ms

0x0000

0x6E94 t_L SLS

:005

Minimum time until the activation of the
SLS_5 safety function, if the speed is
within the window

05

1 ms

0x0000

0x6E94 t_L SLS

:006

Minimum time until the activation of the
SLS_6 safety function, if the speed is
within the window

06

1 ms

0x0000