Product description

AX5805

37

3.6.4.2

Parameterization

Note

Monitoring the reference cam

As soon as the parameters for the reference position have been entered and an external
position is linked with the standard process image, the AX5805 expects to see that the
reference cam input is on every time the reference position is crossed.

By default, AX5000 input 0 is configured to be the Reference Cam hardware input. If the
SLP and SCA functions are not to be used and a Reference Cam will not be wired to a
hardware input on the drive, then Input 0 of the AX5000 must remain unconnected or the
AX5805 reference cam hardware input parameter must configured to an unused input of
the AX5000.

Note

Exceeding the maximum range of travel

If the maximum range of travel is exceeded (over travel)the AX5805 activates STO and
removes torque from the motor. There is no direct possibility to re-activate the axes. There
are three possible methods to re-activate the axes:

-

Bring the axis mechanically back within the defined range (recommended).

-

Force the external position accordingly (not recommended)

-

Parameterize the maximum limits of the range of travel accordingly (not
recommended)

Index

Name

Description

Unit

Default value

0x2010

Reference_Position_Window

Window around the reference
position at which the AX5805
expects the reference cam
(axis 1)

--

0x00000000

0x2011

Reference_Position_Inputpin

Number of the digital input on the
AX5000 to (0 to 7) which the
reference cam is connected
(axis 1)

--

0x00

0x2012

Reference_Position

External position / reference
position, central point of the
reference cam (axis 1)

--

0x00000000

0x2013

Reference_Position_UpperLimit

Maximum external position
(axis 1)

--

0x00000000

0x2014

Reference_Position_LowerLimit

Minimum external position (axis 1) --

0x00000000

0x2810

Reference_Position_Window

Window around the reference
position at which the AX5805
expects the reference cam
(axis 2)

--

0x00000000

0x2811

Reference_Position_Inputpin

Number of the digital input on the
AX5000 to which the reference
cam is connected (axis 2)

--

0x00

0x2812

Reference_Position

External position / reference
position, central point of the
reference cam (axis 2)

--

0x00000000

0x2813

Reference_Position_UpperLimit

Maximum external position
(axis 2)

--

0x00000000

0x2814

Reference_Position_LowerLimit

Minimum external position (axis 2) --

0x00000000