AX5805

29

3.6.2.6

Status word default mapping for axis 1 (1st byte, fixed feature set)

Status word default mapping for axis 1 1A00:02 - 1A00:09

Bit

Assignment

Possible setting

Default value

0

Safe Torque Off (Axis 1 STO)

none

0x66400001

1

Safe Speed Monitor (Axis 1 SSM_1)

none

0x66E00101

2

Safe Speed Monitor (Axis 1 SSM_2

none

0x66E00201

3

Safe Operating Stop (Axis 1 SOS_1)

none

0x66680101

4

Safe Speed Range (Axis 1 SSR_1)

none

0x66800101

5

Safe Direction positive (Axis 1 SDIp)

none

0x66D00001

6

Safe Direction negative (Axis 1 SDIn)

none

0x66D10001

7

Error Acknowledge (Axis 1 ErrAck)

none

0x66320001

Figure 14: Status word default mapping for axis 1