3.6.2.3

Control word user mapping for axis 1 (2nd byte, configurable feature set)

Control word user mapping for axis 1 1600:0A - 1600:11
The 8 bits in second half of the Control word for axis 1 can be freely configured to contain up to a total of 8 of
the following functions. E.g. if 6 safe stop instances are chosen, only 2 other instances can be implemented.

Index

Name

Maximum number of instances

0x6630

Restart_Ack

1

0x6650

Safe Stop 1

8

0x6670

Safe Stop 2

8

0x6668

Safe operating stop

8

0x6680

Safe Speed Range

8

0x6690

Safely Limited Speed

8

0x66A0

Safely Limited Position

8

0x66B0

Safely Limited Increment

8

0x66C0

Safe Acceleration Range

8

Figure 11: Control word user mapping for axis 1