2 configure the cdm-625/as for diversity switching, 1 user remote ethernet m&c interface – Comtech EF Data CDS-100 User Manual

Page 43

Advertising
background image

CDS-100 Diversity Switch

MN-CDS100

Modem and Switch Configuration

Revision 1

4–3

4.2 Configure the CDM-625/As for Diversity Switching

CDM-625A Advanced Satellite Modem Installation and Operation Manual

(CEFD P/N MN-CDM625A)

CDM-625 Advanced Satellite Modem Installation and Operation Manual

(CEFD P/N MN-CDM625)

The CDM-625A and CDM-625 Advanced Satellite Modems automatically detect connection to a

diversity switching system – the steps required to configure both modems are therefore minimal,

with some exceptions:

• If the CDM-625/A has the optional IP Packet

Processor

installed and enabled

Redundancy is controlled from the

, 1:1

CDM-625/A Web Server (HTTP) Interface

Redundancy page.

When both the traffic and backup

modems are equipped with the optional

IP Packet Processor and are connected to

the CDS-100 Diversity Switch, there is no

need to use the drop-down menu here, as

Packet Processor Redundancy is enabled

automatically.

If you wish to operate either modem outside of the redundant setup as a standalone unit,

use the drop-down menu to select Packet Processor Redundancy for that specific modem as

Disabled.

• If terrestrial data is not Ethernet and CnC will not be used, then no modem 1:1 redundancy

configuration is needed. Otherwise, if either apply, refer to the sections that follow.

4.2.1 User Remote Ethernet M&C Interface

You may configure one of the CDM-625/A’s four available 10/100 Ethernet ports for M&C

Ethernet. As configured in Dedicated Management Port Mode, when the modem is offline the

M&C-designated port remains functional and available for operation, while the three remaining

ports are unavailable. Otherwise, if none of the 10/100 Ethernet ports are reserved for M&C

operation, all four ports become unavailable when the modem is offline.

1)

This configuration must be enabled on both modems.

2)

You may not configure Dedicated Management Port Mode for use when the

optional IP Packet Processor is installed and enabled. With the IP Packet Processor

enabled, as a means to avoid Ethernet Networking Loops, only one of the

CDM-625/A’s four 10/100 Ethernet Ports is used for each modem at any given time

Advertising