1 non-ip diversity switching configuration, 2 ip diversity switching configuration – Comtech EF Data CDS-100 User Manual

Page 53

Advertising
background image

CDS-100 Diversity Switch

MN-CDS100

Modem and Switch Configuration

Revision 1

4–13

o

The keypad comprises six individual keyswitches. The keys have a positive ‘click’ action

that provides tactile feedback. Enter data via the keypad. Data, prompts, and messages

are displayed on the VFD.

Serial Remote Control – Configuration, monitoring and control of redundant systems is

possible via remote means over an EIA-485 multi-drop bus using the Serial Console

Command Line Interface (CLI), where data is transmitted in asynchronous serial form using

ASCII characters.

Ethernet Remote Control – Configuration, monitoring and control of redundant systems is

possible via remote means over an Ethernet connection using the CDM-7XX Web Server

(HTTP) Interface.

4.6.1 Non-IP Diversity Switching Configuration

Do these steps for setup of the CDM-710GL, -710, or -700 modems for Diversity Switching when

the terrestrial data type is non-Ethernet (e.g., ASI, HSSI, G.703):

Step

Task

1

On both modems, set the redundancy to the Enable state:

CONFIG: AUX (Redundancy Mode) ENA/DIS – set to Enable.

2

Connect all cables to the modems and the CDS-100. This includes the modem and external controller

cables.

Chapter 5. CABLES AND CONNECTIONS

4.6.2 IP Diversity Switching Configuration

Do these steps for setup of the CDM-710GL, -710, or -700 modems for IP Diversity Switching

(i.e., when the terrestrial data type is Gigabit Ethernet (GigE or GbE)):

Step

Task

1

Before you connect the modems to the CDS-100, you must configure the following CDI-70 IP module

settings on the modem. From the modem front panel:

CONFIG: AUX (Redundancy Mode) ENA/DIS set to Disable.

2

On both modems, set the redundancy to the Enable state:

CONFIG: AUX (Redundancy Mode) ENA/DIS set to Enable.

Press ENTER to save your settings.

3

Connect all cables to the modems and the CDS-100. This includes the modem and external controller

cables. Additionally, you will need an Ethernet connection between the modems via a user-provided

Layer 2 switch.

Advertising