Relay ON Setpoint (hi word)

Read/Write Relay ON Setpoint (byte 3 and byte 2)

2

32 bit

Floating

Point

RW

Y

23

17

Relay ON Setpoint (lo word)

Read/Write Relay ON Setpoint (byte 1 and byte 0)

24

18

Relay OFF Setpoint (hi

word)

Read/Write Relay OFF Setpoint (byte 3 and byte 2)

2

32 bit

Floating

Point

RW

Y

25

19

Relay OFF Setpoint (lo

word)

Read/Write Relay OFF Setpoint (byte 1 and byte 0)

26

1A

Relay ON Delay (hi word)

Read/Write Relay turn on Delay time (byte 3 and

byte 2)

2

32 bit

Floating

Point

RW

Y

27

1B

Relay ON Delay (lo word)

Read/Write Relay turn on Delay time (byte 1 and

byte 0)

28

1C

Relay OFF Delay (hi word)

Read/Write Relay turn off Delay time (byte 3 and

byte 2)

2

32 bit

Floating

Point

RW

Y

29

1D

Relay OFF Delay (lo word)

Read/Write Relay turn off Delay time (byte 1 and

byte 0)

30

1E

Relay Energized State

Read/Write Relay 0 - Energized, 1 - De-Energized

1

16 bit

Integer

RW

Y

31

1F

Relay Expiration

Read/Write Expiration Time, used with alarm type (0

- None, 2 - 5min., 3 - 10min., 4 - 15min., 6 - 30min.)

1

16 bit

Integer

RW

Y

32

20

Relay Period

Read/Write Timed Relay Period (0 - 15min., 1 -

30min., 2 - 1hr., 3 - 2hr., 4 - 4hr., 5 - 8hr., 6 - 24hr.)

1

16 bit

Integer

RW

Y

33

21

Relay Duration

Read/Write Timed Relay Duration (0 - 15sec., 1 -

30sec., 2 - 1min., 3 - 2min., 4 - 5min., 5 - 15min., 6 -

10min.)

1

16 bit

Integer

RW

Y

34

22

Relay Hold Time

Read/Write Timed Relay Hold Time (0 - Off, 1 - held

for the duration time, 2 - duration + 15sec., 3 - duration

+ 30sec., 4 - duration + 1min., 5 - duration + 2min., 6 -

duration + 5 min., 7 - duration + 15min., 8 - duration +

30min.)

1

16 bit

Integer

RW

Y

35

23

4-20 mA Channel Number to

read/write

4-20 mA channel number to access data (0 - 1st 4-

20mA, 1 - 2nd 4-20)

1

16 bit

Integer

RW

Y

36

24

4-20 Analog Type

Read/Write 4-20 Type (0 - Range, 1 - Temperature, 2

- Sentinel)

1

16 bit

Integer

RW

Y

37

25

4-20 Analog Range, 4mA

range (hi word)

Read/Write 4mA range (bytes 3 and 2) applies to

both range and temperature types

2

32 bit

Floating

Point

RW

Y

38

26

4-20 Analog Range, 4mA

range (lo word)

Read/Write 4mA range (bytes 1 and 0) applies to

both range and temperature types

39

27

4-20 Analog Range, 20mA

range (hi word)

Read/Write 4mA range (bytes 3 and 2) applies to

both range and temperature types

2

32 bit

Floating

Point

RW

Y

40

28

4-20 Analog Range, 20mA

range (lo word)

Read/Write 4mA range (bytes 1 and 0) applies to

both range and temperature types

41

29

Long Tag Line number to

read/write

Tag Line number to access data (0 - Line 1, 1 - Line 2)

1

16 bit

Integer

RW

Y

42

2A

Long Tag Line 1 (16

characters max)

ASCII character bytes 0 and 1, ex. "AB" A - 65 (41

hexadecimal), B - 66 (42 hex), send 6566 (4142 hex).

The characters permitted are space ' ' (32 base 10, 20

hex) through '}' 125 base 10, 7D hex).

1

16 bit

Integer

RW

Y

43

2B

Long Tag Line

ASCII bytes 2 and 3

1

16 bit

Integer

RW

Y

44

2C

Long Tag Line

ASCII bytes4 and 5

1

16 bit

Integer

RW

Y

45

2D

Long Tag Line

ASCII bytes 6 and 7

1

16 bit

Integer

RW

Y

46

2E

Long Tag Line

ASCII bytes 8 and 9

1

16 bit

Integer

RW

Y

47

2F

Long Tag Line

ASCII bytes 10 and 11

1

16 bit

Integer

RW

Y

48

30

Long Tag Line

ASCII bytes 12 and 13

1

16 bit

Integer

RW

Y

49

31

Long Tag Line

ASCII bytes 14 and 15

1

16 bit

Integer

RW

Y

50

32

Initiate T80 Parameter

Storage

Signals the user has completed entering the data and

wants it stored. Write any value.

1

16 bit

Integer

RW

51

33

Sensor Channel to

read/write

Sensor channel number to access data (0 - Sensor 1,

1 - Sensor 2)

1

16 bit

Integer

RW

52

34

S80 Mode

Unit operating mode (0-

1

16 bit

Integer

R

53

35

70