Possible relay
contact functions

(9)

Relay output terminals

NC1

NC for relay contact 1

SC1

Relay contact 1

NO1

NO for relay contact 1

NC2

NC for relay contact 2

SC2

Relay contact 2

NO2

NO for relay contact 2

Cable cross-section: 0.5 - 6 mm²
Tightening torque of terminals: 0.8 - 1.6 Nm
Max. continuous current: 16 A
Switching load: 500 mW (10 V / 5 mA)
Switching capacity: 16 A / 250 V (AC1) and 16 A / 30 V (DC1)
The relay outputs are not protected.

Relay contacts can be assigned different functions in the Basic service menu. The
access code 22742 must be entered to access the Basic service menu:
-

Press the 'Menu' key

-

Select 'Setup' mode

-

Press the unassigned 'Esc' button five times

-

Enter the access code 22742

-

Select the 'Switch contact 1' or 'Switch contact 2' parameter

-

Set the desired relay contact function

(10)

F2 fuse, 4 A slow-blow

Item

Description

| NC1 SC1 NO1 | NC2 SC2 NO2 |

Function

Switch contact ac-
tivation criterion

1)

Switch contact de-
activation criteri-
on

2)

Description

Off

-

Permanently OFF

Function switched
off

On

Permanently ON

-

Test function for NO/
alarm contact

AC Open

AC contactor is open

AC contactor is
closed

No contactor error
signal or AC grid

Advertising