Fronius Agilo 75.0 User Manual

Page 93

Advertising
background image

91

EN

Remedy

If the status code is displayed all the time: notify a Fronius-
trained service engineer

407
Internal temperature sensor defective

Behaviour

The inverter is disconnected from the grid for safety reasons.

Remedy

If the status code is displayed all the time: notify a Fronius-
trained service engineer

412
Fixed voltage mode has been selected instead of MPP voltage mode, and the fixing volt-
age has been set at too low or too high a value.

Behaviour

The fixed voltage is lower than the current MPP voltage.

Remedy

Check module voltage and change the connection of the solar
modules if the input voltage is too high;
If the status code appears all the time: notify a Fronius-trained
service engineer

415
External Emergency Stop line is blocked

Behaviour

The inverter is disconnected from the grid for safety reasons.

Remedy

Fault is rectified automatically;
If this status code keeps recurring: notify a Fronius-trained ser-
vice engineer

416
No communication possible between power stage set and control system

Behaviour

The inverter is disconnected from the grid for safety reasons.

Remedy

If the status code is displayed all the time: notify a Fronius-
trained service engineer

425
No communication possible with the power module

Behaviour

The inverter is disconnected from the grid for safety reasons
and then attempts a restart.

Remedy

If the status code is displayed all the time: notify a Fronius-
trained service engineer

426
Intermediate circuit charging takes too long

Behaviour

Short-term interruption while feeding energy into the grid
The inverter resumes with its startup routine.

Remedy

Fault is rectified automatically
If this status code keeps recurring, contact your system engi-
neer