Fronius Agilo 75.0 User Manual

Page 94

Advertising
background image

92

427
Power stage set not ready for too long (timeout)

Behaviour

Short-term interruption while feeding energy into the grid
The inverter resumes with its startup routine.

Remedy

Fault is rectified automatically
If this status code keeps recurring, contact your system engi-
neer

431
Bootloading process interrupted

Behaviour

The inverter is in bootloading mode and is not feeding any en-
ergy into the grid

Remedy

Repeat the update process
If the status code is displayed all the time: notify a Fronius-
trained service engineer

436
Receiving incorrect fault information from the power stage set

Behaviour

Short-term interruption while feeding energy into the grid
The inverter resumes with its startup routine.

Remedy

Fault is rectified automatically
If this status code keeps recurring, contact your system engi-
neer

437
General error handling started in the power stage set

Behaviour

Short-term interruption while feeding energy into the grid
The inverter resumes with its startup routine.

Remedy

Fault is rectified automatically
If this status code keeps recurring, contact your system engi-
neer

438
Receiving incorrect fault information from the power stage set

Behaviour

Short-term interruption while feeding energy into the grid
The inverter resumes with its startup routine.

Remedy

Fault is rectified automatically
If this status code keeps recurring, contact your system engi-
neer

445
-

Compatibility error (e.g. due to replacement of a PC board)

-

Invalid power stage set configuration

Behaviour

The inverter is not feeding any energy into the grid.