Unsuitable loca-
tions

Do not install the inverter:
-

in living areas

-

in rooms where the device will be directly exposed to water

-

in rooms subject to heavy accumulations of dust

-

in rooms in which a heavy build-up of dust containing conductive particles (e.g. iron
chips) is likely

-

in rooms containing caustic vapours, acids or salts

-

in places where there is an increased risk of damage from farm animals (horses, cat-
tle, sheep, pigs, etc.)

-

in stables or adjoining areas

-

in storage areas for hay, straw, chaff, animal feed, fertilisers, etc.

-

in storage or processing areas for fruit, vegetables or winegrowing products

-

in rooms used in the preparation of grain, green fodder or animal feeds

-

in greenhouses

Maintain the following lateral clearances between the inverter and a wall:

*

Wall - left side of inverter:

min. 400 mm (to permit the door to be opened fully and its catch to be latched)

min. 50 mm (to open the door 90°, door catch not latched)

**

Wall - right side of inverter:

min. 250 mm (to permit the air inlet grille to be opened fully)

Two or more inverters can be placed side-by-side or back-to-back.
The clearance between the top of the inverter and the ceiling must be at least 450 mm in
order to prevent air from accumulating.
If the clearance is less than this, install an extractor.
The airflow within the inverter is from the front to the top (cold air taken in at the front, hot
air emitted out of the top).
If the inverter is installed in an enclosed space, then forced-air ventilation must be provid-
ed to ensure adequate heat dissipation.

450 mm

400 mm*

0 mm

250 mm**