2 resolution and maximum speed tables, Resolution and maximum speed tables – MicroE Mercury II 6000 User Manual

Page 23

Advertising
background image

Appendix

IM-Mercury_II_6000 Series Rev. 1

Page 22

©2014 MicroE Systems

Mercury

II

6000 Series Encoders

Installation Manual and Reference Guide

7.2

Resolution and Maximum Speed Tables

Resolution and Maximum Speed Tables - Quadrature Output

Mercury II 6000 systems (models 6500/6700/6800) have programmable interpolation from x4 to
x16384 in integer steps. Below are tables of sample values. For applications requiring up to
10m/s at full resolution, use the MII6800Si/Pa with high speed serial interface.

Linear

– 20µ Grating Pitch

Maximum

Interpolation

Resolution

Maximum

Speed*

Applicable Models

x 4

5.000µm/count

10000mm/sec

6500, 6700, 6800

x 10

2.000µm/count

10000mm/sec

6500, 6700, 6800

x 20

1.000µm/count

10000mm/sec

6500, 6700, 6800

x 40

0.500µm/count

10000mm/sec

6500, 6700, 6800

x 80

0.250µm/count

10000mm/sec

6500, 6700, 6800

x 100

0.200µm/count

10000mm/sec

6500, 6700, 6800

x 200

0.100µm/count

5000mm/sec

6500, 6700, 6800

x 400

0.050µm/count

2500mm/sec

6500, 6700, 6800

x 1000

20.0nm/count

1000mm/sec

6700, 6800

x 2000

10.0nm/count

500mm/sec

6700, 6800

x 4000

5.00nm/count

250mm/sec

6700, 6800

x 8000

2.50nm/count

125mm/sec

6800

x 16384

1.22nm/count†

61mm/sec

6800

Note:

†Value rounded for readability; use the following formula to calculate the exact resolution
in units of µm/count:

𝑅𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛 =

20µ

𝐼𝑛𝑡𝑒𝑟𝑝𝑜𝑙𝑎𝑡𝑖𝑜𝑛 𝑀𝑢𝑙𝑡𝑖𝑝𝑙𝑖𝑒𝑟

Advertising