0 sensor installation, 1 sensor mounting orientation and tolerances, 2 verify sensor mounting surface height – MicroE Mercury II 6000 User Manual

Page 8: 3 install sensor, Sensor installation, Sensor mounting orientation and tolerances, Verify sensor mounting surface height, Install sensor

Advertising
background image

Sensor Installation

IM-Mercury_II_6000 Series Rev. 1

Page 7

©2014 MicroE Systems

Mercury

II

6000 Series Encoders

Installation Manual and Reference Guide

4.0 Sensor Installation

This section contains instructions for installing the sensor.

4.1

Sensor Mounting Orientation and Tolerances

Refer to the following specifications when installing and aligning the Mercury II 6000 encoder.

Orientation

Tolerances

Mercury II

Sensor Alignment Tolerances

Axis

Alignment Tolerance

X

Direction of Motion

Y

± 0.20mm

Z

± 0.15mm

X

± 1.0°

Y

± 1.0°

Z

± 2.0°

4.2

Verify Sensor Mounting Surface Height

Step

Action

1. Verify that the vertical distance between the reference surface of the sensor and the top of the

scale is as follows:

Tape scale/marker tape after blue protective film is removed: 3.09 mm +/-0.13

Linear or rotary glass scales: 2.93 mm +/-0.13

2. Check the height at a location on the scale where there are no index or limit markers.

4.3

Install Sensor

Step

Action

1. Install the sensor on the mounting surface referencing the appropriate datum surface as

shown in the MII6000 Interface Drawings. Use two M-2 screws to loosely attach the sensor.
Note: Do not tighten the two M2 screws at this time.

2. Use benching pins to locate the sensor if the system's mechanical tolerances are adequate.

Refer to the MII6000 Interface Drawings for recommended locations and heights of pins.

Sensor Axes