Order Guide

IM-Mercury_II_6000 Series Rev. 1

Page 39

©2014 MicroE Systems

Mercury

II

6000 Series Encoders

Installation Manual and Reference Guide

How to Order

Sensors

MII6500, A-quad-B Output, with
Resolution from 5µm to 50nm

MII6800Si, Serial Output, with Output
Resolution up to 1.22nm

MII6510-AB-4000-1-1-0 (example)

MII6810-Si-14-21-1-0 (example)

Low Pass Filter Roll
Off Frequency (kHz)
0=Off (full bandwidth)
1=1khz
2=2khz


100=100kHz

Low Pass Filter Roll Off
Frequency
(% of Sample Rate)
0=Off (full bandwidth)
1=1% of sample rate
2=2% of sample rate


40=40% of sample rate

Limit Logic
1=Active Low (fail safe)
2=Active high

Index Mode
0=No change to position
of index
1=Position reset at
every index

Maximum Output
Frequency
1=12.50 MHz
2=6.25 MHz
3=3.125 MHz
4=1.563 MHz
5=0.781 MHz
6=0.391 MHz
7=0.195 MHz
8=0.098 MHz
9=0.049 MHz
10=0.024 MHz

Number of Fringe
Count Bits*
2=2
3=3


21=21

Interpolation Bits*
2=2
3=3


14=14

Interpolation
(Integer Steps)
4=x4
5=x5


4000=x4000



Si
Si=Serial Interface

AB
AB=A-quad-B output

MII68XX (Cable Length)
MII6810=1m cable
MII6830=3m cable
MII6850=5m cable


MII65XX (Cable
Length)
MII6510=1m cable
MII6530=3m cable
MII6550=5m cable

Note*: Interpolation bits plus fringe bits must be

≤35 bits.