0 stick-on index and limit markers installation, 1 stick-on marker strips, 2 remove markers from strip – MicroE Mercury II 6000 User Manual

Page 68: Stick-on index and limit markers installation, Stick-on marker strips, Remove markers from strip

Advertising
background image

Stick-On Index and Limit Markers Installation

IM-Mercury_II_PurePrecision_Scales Rev. 1

Page 24

©2014 MicroE Systems

Mercury II PurePrecision Tape and Glass Scales
Installation Manual and Reference Guide

5.0 Stick-On Index and Limit Markers Installation

This section provides instructions for installing stick-on index and limit markers for PurePrecision
Laser Tape II Scales and Linear Glass Scales. The markers come in strips with the following
models names:

RIMS - Reflective Index Markers

RLMS - Reflective Limit Markers

Note: For tape scale, make sure the blue protective film is removed before installing markers.

5.1

Stick-On Marker Strips

Stick-On Index and Limit Markers for PurePrecision Laser Tape II (HPTS):

Note*: Limit markers have different reflectivity values for left and right markers.

5.2

Remove Markers from Strip

Index/limit markers must first be removed from the stick-on marker strip.

Note: Index marker is used in this procedure, but the procedure is the same for limit markers.

Note: Put on finger cots before starting the index and limit markers installation.

Step

Action

1. Begin by holding the Limit and Index Marker strip so that the blue protective film is on top and

the reflective surface is on the bottom.

Index Marker Strips, Model RIMS

Limit Marker Strips, Model RLMS

Advertising