Vcm controller technical guide 9, Figure 5: vcm controller w iring diagram, All comm loop wiring is s traight thru – Orion System VCM Controller User Manual

Page 9: Tto t , r to r & shld to shld

Advertising
background image

VCM Controller

Technical Guide

9

Line

V

olt

age

All

Comm

Loop

Wiring

Is

S

traight

Thru

24V

AC

GND

Local

Loop

RS-485

9600

Baud

See

Individual

Component

Wiring

Diagrams

For

Det

ailed

Wiring

Of

Analog

Input

s

And

Output

s

For

S

tand

Alone

Applications,

Connect

T

o

System

Manager

.

For

Network

Applications

Connect

T

o

Next

Controller

And/Or

MiniLink

PD

On

Local

Loop.

G

-

Fan

ON/OFF

Only

R

-

24V

AC

Relay

Output

Dry

Cont

act

s

R2

Thru

R5

May

B

e

U

ser

Configured

For

The

Following:

1

-

H

eating

S

tages

2

-

C

ooling

S

tages

3

-

W

arm-up

Mode

Command

(V

A

V

B

oxes)

4

-

R

eversing

V

alve

(Air

T

o

Air

H

eat

Pump

s)

5

-

R

eheat

Control

(Dehumidification)

6

-

E

xhaust

Fan

Interlock

7

-

P

reheater

For

L

ow

Ambient

Protection

8

-

Alarm

9

-

O

verride

10

-

O

ccupied

1

1-O

A

D

a

m

p

e

r

Note:

A

T

ot

al

Of

20

Relays

Are

A

vailable

By

Adding

Relay

Exp

ansion

B

oards.

All

E

xp

ansion

Board

Relay

Output

s

Are

User

Configurable

As

Listed

A

bove.

Connect

FRP

T

ubing

T

o

High

Pressure

Port

(Bottom

T

ube)

and

Route

T

o

S

tatic

Pressure

Pickup

Probe

Located

In

Unit

Discharge.

Leave

Port

Marked

“Lo”

Open

T

o

Atmosphere

OE271

S.P

.

T

ransducer

S

plice

If

Req’d

Connect

T

o

Exp

ansion

Board

Base

(When

Used)

Connection

Port

For

DigiSensor

RLY1

D1

D2

D3

D4

D5

RAM

C3

C2

U6

PHILIPS

CX6

C1

CX2

U2

PA

L

CX4

U4

TUC-5R

PLUS

YS101816

REV

.

2

V1

V2

V3

V5

V4

TB2

4

NETWORK

T

OKEN

16

32

8

SW1

ADD

2

1

ADDRESS

V6

POWER

GND

24V

AC

L1

D16

R6

C9

SC1

R11

U11

MC34064A

D13

C16

9936

VR2

TB4

R27

C13

R10

VR1

C19

C18

NE5090NPB3192 0PS

U8

CX8

U9

X1

R7

D10

R13

D12

C7

CX10

U10

CX12

U12

U14

CX14

PJ3

PJ2

PJ1

EXP

ANSION

PRESSURE

SENSOR

C17

D15

R26

C20

R25

R24

R22

U15

CX13

U13

C15

R19

R15

C14

D18

D17

PU1

PU2

PU3

PU4

PU5

PU7

D6

D7

D8

D9

D1

1

D14

C12

C10

0-5

VDC

0-1

VDC

JP1

C11

X2

GND

TB3

INPUTS

GND

GND

+VDC

AIN1

AIN2

AIN3

AIN4

AIN5

AOUT1

AOUT2

AIN7

RN4

1

RN5

RS-485

CX5

U5

R

TB1

SHLD

T

COMM

COMM

RN3

1

RN1

U1

CX1

1

LD6

COMM

PWR

LD7

LED1

LED2

LD9

LD8

R1

U7

RV

1

VREF

ADJ

R28

+VREF

5.1

1

V

TEST

POINT

EWDOG

D19

RN2

1

COM1-3

COM4-5

R5

R4

R3

R2

R1

RLY2

RLY3

RLY4

RLY5

CX15

(1

MEG)

HH

P1

C21

CX3

EPROM

U3

W

arning:

24

V

A

C

M

ust

Be

Connected

So

That

All

G

round

W

ires

Remain

Common.

Failure

T

o

Do

So

W

ill

Result

In

Damage

T

o

The

Controllers.

T

to

T

,

R

to

R

&

SHLD

to

SHLD

Size

T

ransformer

For

Correct

T

o

ta

l

Load.

VCM

Controlle

r=8V

A

Power

Consumption.

If

Economizer

Option

Is

Used

The

Economizer

Actuator

V

A

load

Must

Also

Be

Considered

When

Sizing

The

T

ransformer

.

OE331-21-VCM

VCM

Controller

Board

Note:

All

Relay

Output

s

Are

Normally

Open

And

Rated

For

24

V

A

C

Power

Only

.

2

Amp

Maximum

Load.

Figure 5: VCM Controller W

iring Diagram