"Unlocked (No signal)"

When there is no audio signal
"Not Audio"

When Cbit information is not professional
"Not Professional"

When other Cbit information and the actual operation mode
are different
"Unmatched Cbit"

TIMECODE page

Make settings related to time code. The first illustration
below shows the screen when set to Free Run mode, and the
second shows when set to Free Once or Jam Sync mode.

STATUS
This area shows the unit’s time code generator mode and
current project time code frame type.

GENERATOR
The top line shows the time of the current time code
generator.
The bottom line shows the user bits.
Touch the

GENERATOR

item

EDIT

button or the user bit

display area to open the

T/C

USER

BITS

screen.

When the time code generator is in Free Run mode, press
the

RESTART

button to restart the time code generator.

TC IN
The frame type appears at the left side in green.
The top line shows the time of the input time code.
The bottom line shows the user bits of the input time code.
In free run mode, touch the

CAPTURE

button to input the

current time code and set it as the start time of the time code
generator.
If the time code generator mode is Free Once or Jam Sync,
the capture status display (

WAITING

indicator) lights green

when waiting for time code, and it turns off after time code

is captured.

START TIME
When you touch the

GENERATOR

item’s

RESTART

button, the

time when the time code restarts is shown. Touch the

START

TIME

item

EDIT

button or the start time display area to open

the start time setting screen.

SETUP page

Make settings related to the time code generator.

STATUS
This shows the timecode frame type of the current project.

TC GEN MODE
Set the time code generator mode.
FREE RUN: The time code generator runs on its own
FREE ONCE (default value): After the input time code is
captured once, the unit starts free run mode.
TIME OF DAY: When you turn the power ON, set the TC
GEN MODE to this setting or reset the internal clock, the
time is captured from the internal clock and then the unit
starts free run mode.
JAM SYNC: When time code is input, the unit synchronizes
to the input time code. If time code input is interrupted, the
unit enters free run mode.
REGEN: The unit synchronizes to the input time code.
REC RUN: The time code generator only functions during
recording. At all other times, the time code generator stops.

POWER OFF GEN
Set whether or not the time code generator continues to run
when the power is turned on again after being turned off
while it was running. (Default setting:

OFF

)

When set to TIME OF DAY, REGEN or REC RUN this
setting has no effect.
When set to “ON,” the time code continues to advance
even while the power is turned OFF, so when you turn the
power ON again, the time code generator restarts with a
continuation of the running time. This makes capturing the
time code again and other preparations unnecessary.
However, since this function uses the built in clock as the
basis for interpolation, sometimes a small error might occur
in the value of the restarted time code.
When frame type is 23.976F, 29.97DF, 29.97ND, 30DF,
deviation will be larger.