Message

Details and responses

Remarks

Digital Input Error

AES1-2 (Unlocked)
AES3-4 (no signal)
AES5-6 (not audio)
AES7-8 (unmatched Cbit)

An error occurred with the digital input

selected for the input signal.

• Unlocked:

not synchronized with system

• no signal:

no signal is being input

• not audio:

Cbit information of input signal is

not audio

• not professional:

Cbit information of input signal is

consumer

• unmatched Cbit:

other Cbit information of input

signal is different from actual

operation mode

External Clock Lost,
Switched to Internal

Synchronization with an external clock

was disrupted, so the internal clock was

activated.

External Clock Regained

Switch to External?

Synchronization with an external clock

became possible again.

EXTERNAL DC Power Lost,

Switched to INTERNAL BATTERY

External DC power was lost, so the internal

battery was activated.

EXTERNAL DC power

now available,

Switch to EXTERNAL DC?

While operating using the internal battery,

external DC power became available.

EXTERNAL DC Voltage too low,
Switched to INTERNAL BATTERY

The voltage of the external DC battery

became low, so the internal battery was

actived.

Input Volume Locked

Input Volume

is locked

The input volume control has been locked to

prevent misoperation.

INTERNAL BATTERY Power Lost,

Switched to EXTERNAL DC

The internal battery was removed, so the

external DC power source was activated.

INTERNAL

BATTERY

Voltage

too

low,

Switched to EXTERNAL DC

The voltage of the internal battery became

low, so the external DC power source was

activated.

Last loaded project has

no scenes.

Please make new scene.

The most recently loaded project does not

have any scenes. Create a new scene.

Last loaded project

cannot be found.

Please select a project.

The last selected project cannot be found.

Select a different project.

Last loaded scene

cannot be found.

Please select a scene.

The last selected scene cannot be found.

Select a scene.

Load selected project?

""pppppppp""

Confirm that you want to load the selected

project.

pppppppp = name of project to load

Load selected Scene?

""ssssssss""

Confirm that you want to load the selected

scene.

ssssssss = name of scene to load

Load selected Take?

""tttttttt""

Confirm that you want to load the selected

take.

tttttttt = name of take to load

Loading Project...

The project is loading.

Loading Scene...

The scene is loading.

Loading Take...

The take is loading.

Lost all power.

Shutdown automatically

in 20 seconds.

All power sources have been lost. The unit

will automatically shut down in 20 seconds.

Make new scene?

""ssssssss""

Confirm that you want you want to make a

new scene.

ssssssss = scene name

Make Scene failed

Creation of the scene failed.

Making Scene...

The scene is being created.

Mark Point set

The mark has been created.

New Scene Name must not

start with ""@""

The scene name is not allowed. A scene

name must not start with the "@" mark.

No Call Point

The call point does not exist.

10 – Messages