Level meter settings (meter setup), 6 – internal settings and operations – Teac HS-P82 User Manual

Page 45

Advertising
background image

TASCAM HS-P82

45

Level knob: Touch the knob to adjust the level sent to the

stereo bus. When its background color turns yellow, use
the

DATA

dial to adjust it. Setting values range from “–∞”

dB –

+10

dB. (Default setting:

0dB

)

Pan pot knob: Touch the knob to adjust the stereo position

of the signal sent to the stereo bus. When its background
color turns yellow, use the

DATA

dial to adjust it. Setting

values range from

L100

to

R100

with

C

as the center

value. (Default setting:

C

)

Level meter: During playback, the meter shows the

playback level. For tracks that have the record function
ON and are not playing back, the meter shows the input
signal level.

The area at the bottom of the level meter shows the track
name (4 characters or less) and acts as a record function
indicator. If the MIC/LINE selection switch for the
current channel is set to MIC 0 or MIC –25, the name
area momentarily shows the gain value when you turn
the input trim knob. If the input source is set to a digital
and there is no signal on the corresponding digital input
or the input signal differs from the unit setting, the
channel meter display appears gray and the following
messages appear.

If there is no corresponding input,

AESx-x

NO

SIGNAL

.

If the input signal differs from the settings made in the

unit,

AESx-x

UNLOCK

.

If the Cbit information of the input signal is no audio,

AESx-x

NOT

AUDIO

.

If the Cbit information of the input signal is non

professional,

AESx-x

NOT

PRO

.

If other Cbit information of the input signal differs

from actual operation mode,

AESx-x

Cbit

ERROR

.

Channel name button: Touch this button at the lower right

of the screen to edit the name of the channel.

˙

or

¥

button: Touch this button to open the setting screen

of the next channel.

When channels are linked, the screen appears as follows.

The channel setup screen for the stereo (L/R) channel has
fewer options and appears as follows.

Level meter settings (METER SETUP)

Make level meter settings on this screen.

Peak Hold Time knob: Touch this to set the peak hold time.

Use the

DATA

dial to adjust the time. The setting values

are 0 sec, 1 sec, 2 sec and inf (hold forever). (Default
value:

1 sec

)

Release Time knob: Touch this to set the release time. Use

the

DATA

dial to adjust the time. The setting values are

Slow

,

Normal

and

Fast

. (Default setting:

Normal

)

Over Level knob: Touch this to set the level at which the

overload indicator lights (the amount in dB below the
maximum level). Use the

DATA

dial to adjust the level.

The setting value range is

–0.20

dB

(default value),

–0.17

dB

,

–0.13

dB,

–0.10

dB,

–0.06

dB,

or

–0.03

dB

.

These settings are reflected in the Audio Over setting of
the Auto Marker item on the OPTIONS page of the REC
SETUP screen.

Ref. Level Line button: Touch to turn the reference level

line ON or OFF. (Default setting:

ON

)

NOTE

If you press the EXIT/CANCEL [PEAK CLEAR] key when the
Home Screen is open, the peak hold display resets.

6 – Internal Settings and Operations