52

C

HAPTER

4: T

ERMINAL

I

NTERFACE

period (or the last 96 fifteen-minute intervals). The third line shows the 30-day
totals.

The remaining lines of this screen show the data for any intervals containing
errors. Interval 1 is the most recently stored 15-minute interval and interval 96 is
the oldest in the current 24-hour period. On the 30-day screens, interval 30 is the
oldest 1 -day interval in the current 30 -day period. The real time (or date on
30-day screens) of the interval beginning is shown in the first column.

If more than 5 errored intervals have elapsed, PAGE-DN appears to the left of the
performance data. Pressing <enter> on this field displays the next five errored
intervals. PAGE -UP appears once PAGE -DN is used. Pressing <enter> on
PAGE-UP displays the previous five errored intervals. Only intervals containing
errors are displayed, eliminating rows of zeroes. If an interval is not displayed, no
errors were detected during that time period.

The parameters shown on the Performance screens are updated at approximately
five second intervals.

Per AT&T TR 54016, the Standard 24 Hour and Standard 30 Day performance
data consists of Errored Seconds (ES), Unavailable Seconds (UAS), Bursty Errored
Seconds (BES), Severely Errored Seconds (SES), Loss of Frame Count (LOFC),
and Controlled Slip Seconds (CSS).

The Enhanced 24 Hour and Enhanced 30 Day screens show data for CRC Errored
Seconds (CRCES), Out of Frame Seconds (OOFS), Loss of Signal Seconds
(LOSS), Alarm Indication Signal Seconds (AISS), Remote Alarm Seconds (RAS),
and Bipolar Violation Seconds (BPVS).

For generic 54016 far end devices, only the standard telco network 24-hour
performance data is displayed. 30-day data is not available.