Verilink PRISM 3111 (34-00242) Product Manual User Manual

Page 89

Advertising
background image

RFC 1406 - DS1/E1 MIB

81

dsx1SendLineCode(2) - the unit is transmitting an inband LLB loopup signal.
Since this occurs for less than 6 seconds, this response probably won’t be seen.
dsx1SendPayloadCode(3) - the unit is sending an out-of-band PLB loopup
request to the Far End, but since this happens in a fraction of a second, this
response will probably never be seen
dsx1SendResetCode(4) - the unit is sending either an inband LLB loopdown
signal, or an out-of-band PLB loopdown request, but since these happen so
quickly, this response will probably never be seen
dsx1SendQRS(5) - the unit is in a Network Bert Test transmitting QRSS
pattern
dsx1Send511Pattern(6) - the unit is in a Network Bert Test transmitting 511
pattern
dsx1Send3in24Pattern(7) - the unit is in a Network Bert Test transmitting 3:24
pattern
dsx1SendOtherTestPattern(8) - the unit is in a Network Bert Test and is
transmitting a pattern other than QRSS, 511 or 3:24.

SET:

dsx1SendNoCode(1) - stops any Bert Tests on the unit
dsx1SendLineCode(2) - the unit will transmit an inband LLB loopup signal
dsx1SendPayloadCode(3) - the unit will send an out-of-band PLB loopup
request to the Far End
dsx1SendResetCode(4) - the unit will send either an inband LLB loopdown
signal, or an out-of-band PLB loopdown request, depending on what the Far
End has active
dsx1SendQRS(5) - the unit will start a Network Bert Test transmitting QRSS
pattern
dsx1Send511Pattern(6) - the unit will start a Network Bert Test transmitting
511 pattern
dsx1Send3in24Pattern(7) - the unit will start a Network Bert Test transmitting
3:24 pattern
dsx1SendOtherTestPattern(8) - the unit will start a Network Bert Test,
running a Clear test

dsx1CircuitIdentifier: (read-write)

GET: Returns the value of the Circuit Identifier for the unit, this defaults to
‘TXPORT PRISM 3100’

SET: Sets the Circuit Identifier of the unit to the specified string

dsx1LoopbackConfig: (read-write)

GET:

dsx1NoLoop(1) - the unit does not have any loops active
dsx1PayloadLoop(2) - the unit has a PLB active
dsx1LineLoop(3) - the unit has a LLB active
dsx1OtherLoop(4) - the unit has a Port Loop active