Rfc 1406 - ds1/e1 mib, Dsx1configtable – Verilink PRISM 3111 (34-00242) Product Manual User Manual

Page 88

Advertising
background image

80

A

PPENDIX

A: SNMP A

GENT

testing(3) - returned for the DS1 interface, Port 1 or Port 2 if the interface has
a test loop or BERT active.

ifLastChange: (read-only)

GET:

returns the time in hundredths of a second since the interface was

changed, or reset.

RFC 1406 -
DS1/E1 MIB

This RFC was published in January 1993. It is meant to be a replacement for RFC
1232. RFC 1406 is used to manage DS1 interfaces, and in our case specifically a
T1 interface. The following is a list of the objects contained within this RFC, and
the manner in which the unit responds to each.

dsx1ConfigTable

dsx1LineIndex: (read-only)

GET:

(2) - if a NIC is not installed
(3) - if a NIC is installed

dsx1IfIndex: (read-only)

GET:

(2) - if a NIC is not installed
(3) - if a NIC is installed

dsx1LineType: (read-write)

GET:

dsx1ESF(2) - the Network Framing is set to ESF
dsx1D4(3) - the Network Framing is set to D4

SET:

dsx1ESF(2) - sets the Network Framing to ESF
dsx1D4(3) - sets the Network Framing to D4

dsx1LineCoding: (read-write)

GET:

dsx1B8ZS(2) - the Network Coding is set to B8ZS
dsx1AMI(5) - the Network Coding is set to AMI

SET:

dsx1B8ZS(2) - sets the Network Coding to B8ZS
dsx1AMI(5) - sets the Network Coding to AMI

dsx1SendCode: (read-write)

GET:

dsx1SendNoCode(1) - the unit is not in a Bert Test and not sending a PLB or
LLB loopup/loopdown request to the Far End