Yaskawa SI-EN3D User Manual

Page 45

Advertising
background image

Instance

ID

Attribute

Name

Description

Get

Set

Size

Range

Default

1

6

Drive Mode

Drive control mode.

0: OLV, OLV for PM (Read only),

Advanced OLV for PM (Read only)

1: V/f

2: V/f with PG

3: CLV, CLV for PM (Read only)

O

O

Byte

0 to 3

0

1

7

Speed Actual

Actual drive speed.

Unit is not affected by Speed Scale

(SS).

O

Word

3

1

8

Speed Reference

Frequency Reference.

Monitors the drive frequency

reference.

Unit is not affected by Speed Scale

(SS).

O

O

Word

0

1

9

Current Actual

Actual Output Current.

Display is in the following units:

2A0004 to 2A0040, 4A0002 to

4A0023, 5A0007 to 5A0017: 0.01 A

units.

2A0056 to 2A0415, 4A0031 to

4A0675, 5A0022 to 5A0242: 0.1 A

units.

4A0930 and 4A1200: 1 A units.

Unit is not affected by Current Scale

(CS).

O

Word

0

1

11

Torque Actual Drive Output Torque Unit is affected

by Torque Scale (TS)

O

Word

0

1

12

Torque

Reference/

Torque Limit

Torque Reference/Torque Limit

Sets the Torque Reference/Torque

Limit. The units are determined by the

Torque Scale.

Sets the Torque Reference when using

Torque Control (d5-01 = 1).

Sets the Torque Limit when using

Speed Control (d5-01 = 0)

The Torque Reference/Torque Limit

are disabled when F6-06 = 0.

O

O

Word

0

1

15

Power Actual

(W)

Drive Output Power Unit is affected by

Power Scale (PS).

O

Word

0

1

16

Input Voltage

(V)

Drive Input Voltage

Unit is affected by Voltage Scale (VS).

O

Word

Dep. on capacity

1

17

Output Voltage

(V)

Drive Output Voltage

Unit is affected by Voltage Scale (VS).

O

Word

0

1

18

Accel Time (ms)

Acceleration Time 1 (C1-01)

Units set in parameter C1-10.

Unit is affected by Time Scale (TS).

O

O

Word

2710H

1

19

Decel Time (ms)

Acceleration Time 1 (C1-02)

Units set in parameter C1-10.

Unit is affected by Time Scale (TS).

O

O

Word

2710H

1

20

Low Speed

Limit Percent of

Max Speed

Frequency Reference Lower Limit

(d2-02)

O

O

Word

0 to 1100

0

1

21

High Speed

Limit Percent of

Max Speed

Frequency Reference Upper Limit

(d2-01)

O

O

Word

0 to 1100

3E8H

1

22

Speed Scale

(-15 to 15)

Setting for F7-17, scale of units for

speed related data.

O

O

Byte

-15 to 15

0

1

23

Current Scale

(-15 to 15)

Setting for F7-18, scale of units for

current related data.

O

O

Byte

-15 to 15

0

1

24

Torque Scale

(-15 to 15)

Setting for F7-19, scale of units for

torque related data.

O

O

Byte

-15 to 15

0

1

26

Power Scale

(-15 to 15)

Setting for F7-20, scale of units for

power related data.

O

O

Byte

-15 to 15

0