Fault codes, Major fault – Yaskawa GPD 506/P5 Section Three User Manual

Page 16

Advertising
background image

PP.P5G5.03.Troubleshoot

Page 16

Rev. 06/11/2003

After initial communication has been established, the
connection was then lost.

Response may be selected.

BUS

SI-B Com Err

Possible Cause(s):

Connection is broken, master has stopped communicating.

Corrective Action:

Check all connections, verify all user side software configurations.

505

N/A

Fault Codes

Major Fault

- Motor coasts to a stop, the fault is displayed on the digital

operator, and the fault relay is activated.

Possible Cause(s):

Connection is broken, master has stopped communicating.

Corrective Action:

Check all connections, verify all user side software configurations.

CE

Memobus Com Err

Transmission error. Control data was not received
normally when the power supply is turned on.

Response may be selected.

ce

506

515

506

515

505

Advertising