Fault codes – Yaskawa GPD 506/P5 Section Three User Manual

Page 43

Advertising
background image

PP.P5G5.03.Troubleshoot

Page 43

Rev. 06/11/2003

Fault Codes

G5

G5 P5

Major Minor

Parameter

G5

MODBUS

Code

Text

Code

Fault Fault Setting Error Register Data Page #

OC

Over current

OC

X

07

64

OH

Heatsnk Overtemp

OH1

X

85

OH1

Heatsnk MAX Temp

OH2

X

0A

72

OH2

Over Heat 2

OH3

X

85

OL1

Motor Overloaded

OL1

X

0B

66

OL2

Inv Overloaded

OL2

X

0C

66

OL3

Overtorque Det 1

OL3

X

X

0D

67,86

OL4

Overtorque Det 2

N/A

X

X

0E

67,86

OPE01

KVA Selection

OPE1

X

92

OPE02

Limit

OPE6

X

92

OPE03

Terminal

OPE3

X

93

OPE05

Sequence Error

N/A

X

93

OPE06

PG Opt Missing

N/A

X

94

OPE07

Analog Selection

N/A

X

94

OPE08

Terminal

N/A

X

95

OPE10

V/F Ptrn Setting

OPE5

X

95

OPE11

FC/ On-Dly

N/A

X

96

OPR

Oper Disconnect

OPr

X

1E

72

OS

Overspeed Det

N/A

X

X

18

69,89

OV

DC Bus Overvolt

OU

X

X

08

63,84

PF

Input Pha Loss

SP1

X

1B

68

PGO

PG Open

N/A

X

X

1A

69,89

PUF

DC Bus Fuse Open

PUF

X

01

65

RH

DynBrk Resistor

N/A

X

10

70

RR

DynBrk Transistr

N/A

X

0F

70

SC

Short Circuit

SC

X

05

65

SVE

Zero Servo Fault

N/A

X

26

71

UV

DC Bus Undervolt

Uu

X

84

UV1

DC Bus Undervolt

UU1

X

02

62

UV2

CTL PS Undervolt

UU2

X

03

62

UV3

MC Answerback

UU3

X

04

63

Note: When communicating with the GPD 515/G5 using the internal MODBUS protocol,