Fault codes, Major fault – Yaskawa GPD 506/P5 Section Three User Manual

Page 19

Advertising
background image

PP.P5G5.03.Troubleshoot

Page 19

Rev. 06/11/2003

505

Fault Codes

Major Fault

- Motor coasts to a stop, the fault is displayed on the digital

operator, and the fault relay is activated.

EEPROM internal data does not match the value in

RAM when setting a parameter.

ERR

EEPROM R/W Err

N/A

Possible Cause(s):

Control board hardware failure.

Corrective Action:

Cycle power, replace the control board.

The deviation of the speed reference and speed

feedback has exceeded the regulation level.

A minor fault contact output can be programmed by

using the multi-function outputs.

DEV

Speed Deviation

N/A

Possible Cause(s):

The load has changed considerably.

Corrective Action:

Check the load on the motor, verify the program settings (F1-10 PG

Deviate Level, F1-11 PG Deviate Time. F1-04 PG Deviation Select.

506