Fault codes, Major fault – Yaskawa GPD 506/P5 Section Three User Manual

Page 25

Advertising
background image

PP.P5G5.03.Troubleshoot

Page 25

Rev. 06/11/2003

CPF23

Option DPRAM Err

DPRAM handshake timing between the 515/G5 and a
network or communication option card has timed out.

N/A

Possible Cause(s):

An option board is not correctly connected to the control board, an

option board that is not made for the 515/G5 inverter is attached to the control board.

Corrective Action:

Remove power to the inverter and connect the option board once more.

Perform a factory initialization , cycle power, replace the option board, replace the control
board.

Fault Codes

Major Fault

- Motor coasts to a stop, the fault is displayed on the digital

operator, and the fault relay is activated.

505

506

515

Advertising