Fault codes, Minor fault – Yaskawa GPD 506/P5 Section Three User Manual

Page 31

Advertising
background image

PP.P5G5.03.Troubleshoot

Page 31

Rev. 06/11/2003

The motor speed has exceeded the overspeed level

when operating in the Closed Loop V/f or Closed

Loop Flux Vector modes.

OS

Overspeed Det

N/A

Feedback pulses are not received by the PG option

board.

PGO

PG open

N/A

Possible Cause(s):

The load has changed considerably, the program settings are not set

correctly.

Corrective Action:

Check the load on the motor, verify the program settings (F1-08 PG

Overspeed Level, and F1-09 PG Overspeed Time).

Possible Cause(s):

The Pulse Generator feedback wires may be broken or not properly

connected to the PG feedback option board, torque limit set too low, motor shaft locked.

Corrective Action:

Check for a broken wire or a loose connection from the Pulse

Generator, verify the program settings (F1-01 PPR, and F1-02 Feedback Loss Select),
increase the torque limits.

Fault Codes

Minor Fault

- Operation continues and the digital operator indication blinks

The fault relay does not activate.

505

506

515

Advertising
This manual is related to the following products: