CPF21

Option CPU down

The CPU on the SI-B option board has locked up.

N/A

CPF22

Option Type Err

DPRAM fault detected at power up.

N/A

Possible Cause(s):

Noise or spike on the communication line, defective SI-B option board.

Corrective Action:

Perform a factory initialization , cycle power, replace the option board,

replace the control board.

Possible Cause(s):

Unrecognizable communication or network option board is connected to

the control board.

Corrective Action:

Remove any option boards and cycle power, perform a factory initialization,

replace the option board, replace the control board.