Fault codes, Minor fault – Yaskawa GPD 506/P5 Section Three User Manual

Page 32

Advertising
background image

PP.P5G5.03.Troubleshoot

Page 32

Rev. 06/11/2003

The deviation of the speed reference and speed

feedback has exceeded the regulation level.

A minor fault contact output can be programmed by

using the multi-function outputs.

DEV

Speed Deviation

N/A

Possible Cause(s):

The load has changed considerably.

Corrective Action:

Check the load on the motor, verify the program settings (F1-10 PG

Deviate Level, F1-11 PG Deviate Time. F1-04 PG Deviation Select.

Possible Cause(s):

Connection is broken, master has stopped communicating.

Corrective Action:

Check all connections, verify all user side software configurations.

CE

Memobus Com Err

Transmission error. Control data was not received
normally when the power supply is turned on.

Response may be selected.

ce

Fault Codes

Minor Fault

- Operation continues and the digital operator indication blinks

The fault relay does not activate.

505

506

515

505

506

515

Advertising