3 slave mode, 4 functional outline, I/o communications – Yaskawa 260IF DeviceNet System User Manual

Page 18: Message communications

Advertising
background image

Outline

1.1.3 Slave Mode

1-4

1

1.1.3 Slave Mode

The following diagram shows the system configuration when the 260IF Module is used in
Slave Mode.

1.1.4 Functional Outline

I/O Communications

The I/O communications function uses DeviceNet I/O connections to exchange data
between DeviceNet devices connected on the communications path and the MP900 Machine
Controller.

The CP-717 Engineering Tool is used to allocate I/O registers in the Controller’s CPU for I/
O communications.

Message Communications

The message communications function sends explicit messages that read the DeviceNet
device names or serial numbers and write parameters for DeviceNet devices.

The MSG-SND function is used for message communications.

260IF

MP920

I/O

PS

PS

I/O

PS

FG

260IF

MP920

Internal I/O power supply

External I/O power supply

Master Mode

Slave Mode

Terminating

resistance
121

Trunk line
Drop line
External I/O power supply line
Internal I/O power supply line
Communications power supply line

Terminating resistance
121

Communications Power

Supply Tap (with

reverse-current preven-

tion for multiple power

supply units)

Communications
power supply

Advertising