KACO Powador XP200-HV TL User Manual

Page 17

Advertising
background image

Mounting the inverter

Operating Instructions Powador XP200-HV TL, XP250-HV TL, XP350-HV TL_EN

Page 17

Electrician

XP200-HV TL

Measurand

Internal consumption in standby

Internal consumption in operation

I

trms

[A]

0.53

2.35

V

trms

[V]

216.6

214.9

P [W]

77.3

346.3

S [VA]

114.5

504.0

Q [Var]

84.5

366.2

Table 3:

Power consumption data of XP200-HV

XP250-HV TL

Measurand

Internal consumption in standby

Internal consumption in operation

I

trms

[A]

0.53

2.41

V

trms

[V]

219.0

217.7

P [W]

79.9

351.8

S [VA]

115.7

525.2

Q [Var]

83.7

390.0

Table 4:

Power consumption data of XP250-HV

XP350-HV TL

Measurand

Internal consumption in standby

Internal consumption in operation

I

trms

[A]

0.80

3.41

V

trms

[V]

216.9

215.0

P [W]

99.4

486.0

S [VA]

174.5

732.5

Q [Var]

143.5

548.1

Table 5:

Power consumption data of XP350-HV TL