3 mmi main menu, Mmi main menu, 1 changing the sd card, status display – KACO Powador XP200-HV TL User Manual

Page 41: Danger

Advertising
background image

User interface

Operating Instructions Powador XP200-HV TL, XP250-HV TL, XP350-HV TL_EN

Page 41

8.3

MMI main menu

ON OFF

PV

generator

Inverter

Grid

Circuit breaker CB10

Speaker

SD card

Circuit breakers

MC21 + CB20

Fault

History

Statistics

Setup

701.0V

External Limitation

Today: 0.0 kWh

Total: 0.0 kWh

400.0V

75.8kW

79.0kW

45.0°C

Date/Time

Displayed button colours

Colour

Meaning

Green

Normal operation

Red

Fault
(not for switches CB10, MC21 and CB20)

Grey

Not in use

Figure 40: Display when the MMI starts up

8.3.1 Changing the SD card, status display

DANGER

Lethal voltages are still present in the terminals and lines of the inverter even after the inver-

ter has been switched off and disconnected!
Coming into contact with the lines and terminals in the inverter will cause serious injury or death.
Only authorised electricians who are approved by the supply grid operator may open, install and

maintain the inverter.

Shut down the inverter before opening it.

Do not touch the lines and terminals when switching the unit on and off!

Insert the SD card
“No SD in slot” icon
1. Shut down the inverter.
2. Open the inverter.
3. Slide the SD card into the slot until it locks into place.
4. Close the inverter.
5. Press the “ON” button. The inverter starts up.
“SD card in slot” icon
The inverter checks the card. If the SD card was detected, the “SD card in slot” icon appears in the

lower right-hand corner of the display.
1. Press the SD card icon.
2. Wait until the SAFE icon is displayed.

Advertising